Integrated positron emission tomography and magnetic resonance imaging–guided resection of brain tumors: a report of 103 consecutive procedures

Author:

Pirotte Benoît1,Goldman Serge1,Dewitte Olivier1,Massager Nicolas1,Wikler David1,Lefranc Florence1,Ben Taib Nordeyn Oulad1,Rorive Sandrine1,David Philippe1,Brotchi Jacques1,Levivier Marc1

Affiliation:

1. Departments of Neurosurgery, Neuropathology, and Neuroradiology; and PET/Cyclotron Biomédical Unit, Hôpital Erasme, Université Libre de Bruxelles, Brussels, Belgium

Abstract

Object The aim of this study was to evaluate the integration of positron emission tomography (PET) scanning data into the image-guided resection of brain tumors. Methods Positron emission tomography scans obtained using fluorine-18 fluorodeoxyglucose (FDG) and l-[methyl-11C]methionine (MET) were combined with magnetic resonance (MR) images in the navigational planning of 103 resections of brain tumors (63 low-grade gliomas [LGGs] and 40 high-grade gliomas [HGGs]). These procedures were performed in 91 patients (57 males and 34 females) in whom tumor boundaries could not be accurately identified on MR images for navigation-based resection. The level and distribution of PET tracer uptake in the tumor were analyzed to define the lesion contours, which in turn yielded a PET volume. The PET scanning–demonstrated lesion volume was subsequently projected onto MR images and compared with MR imaging data (MR volume) to define a final target volume for navigation-based resection—the tumor contours were displayed in the microscope’s eyepiece. Maximal tumor resection was accomplished in each case, with the intention of removing the entire area of abnormal metabolic activity visualized during surgical planning. Early postoperative MR imaging and PET scanning studies were performed to assess the quality of tumor resection. Both pre- and postoperative analyses of MR and PET images revealed whether integrating PET data into the navigational planning contributed to improved tumor volume definition and tumor resection. Metabolic information on tumor heterogeneity or extent was useful in planning the surgery. In 83 (80%) of 103 procedures, PET studies contributed to defining a final target volume different from that obtained with MR imaging alone. Furthermore, FDG-PET scanning, which was performed in a majority of HGG cases, showed that PET volume was less extended than the MR volume in 16 of 21 cases and contributed to targeting the resection to the hypermetabolic (anaplastic) area in 11 (69%) of 16 cases. Performed in 59 LGG cases and 23 HGG cases, MET-PET demonstrated that the PET volume did not match the MR volume and improved the tumor volume definition in 52 (88%) of 59 and 18 (78%) of 23, respectively. Total resection of the area of increased PET tracer uptake was achieved in 54 (52%) of 103 procedures. Conclusions Imaging guidance with PET scanning provided independent and complementary information that helped to assess tumor extent and plan tumor resection better than with MR imaging guidance alone. The PET scanning guidance could help increase the amount of tumor removed and target image-guided resection to tumor portions that represent the highest evolving potential.

Publisher

Journal of Neurosurgery Publishing Group (JNSPG)

Cited by 133 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司