Abstract

OBJECT Spacers placed between the lumbar spinous processes represent a promising surgical treatment alternative for a variety of spinal pathologies. They provide an unloading distractive force to the stenotic motion segment, restoring foraminal height, and have the potential to relieve symptoms of degenerative disc disease. The authors performed a retrospective, multicenter nonrandomized study consisting of 1108 patients to evaluate implant survival and failure modes after the implantation of 8 different interspinous process devices (IPDs). METHODS The medical records of patients who had undergone placement of an IPD were retrospectively evaluated, and demographic information, diagnosis, and preoperative pain levels were recorded. Preoperative and postoperative clinical assessments in the patients were based on the visual analog scale. A minimum of 3 years after IPD placement, information on long-term outcomes was obtained from additional follow-up or from patient medical and radiological records. RESULTS One thousand one hundred eight patients affected by symptomatic 1- or 2-level segmental lumbar spine degenerative disease underwent placement of an IPD. The complication rate was 7.8%. There were 27 fractures of the spinous process and 23 dura mater tears with CSF leakage. The ultimate failure rate requiring additional surgery was 9.6%. The reasons for revision, which always involved removal of the original implant, were acute worsening of low-back pain or lack of improvement (45 cases), recurrence of symptoms after an initial good outcome (42 cases), and implant dislocation (20 cases). CONCLUSIONS The IPD is not a substitute for a more invasive 3-column fusion procedure in cases of major instability and spondylolisthesis. Overdistraction, poor bone density, and poor patient selection may all be factors in the development of complications. Preoperatively, careful attention should be paid to bone density, appropriate implant size, and optimal patient selection.

Publisher

Journal of Neurosurgery Publishing Group (JNSPG)

Subject

Neurology (clinical),General Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3