Enhancing outcomes in deep brain stimulation: a comparative study of direct targeting using 7T versus 3T MRI

Author:

Middlebrooks Erik H.12,Tipton Philip W.3,Greco Elena1,Okromelidze Lela1,Patel Vishal1,Wszolek Zbigniew K.3,Zhou Xiangzhi1,Tao Shengzhen1,Westerhold Erin M.1,Straub Sina1,Uitti Ryan J.3,Sandhu Sukhwinder Johnny Singh1,Quiñones-Hinojosa Alfredo2,Grewal Sanjeet S.2

Affiliation:

1. Departments of Radiology,

2. Neurosurgery and Neuroscience, and

3. Neurology, Mayo Clinic, Jacksonville, Florida

Abstract

OBJECTIVE The aim of this study was to compare outcomes of direct targeting in deep brain stimulation (DBS) for essential tremor using 7T MRI versus 3T MRI. The authors hypothesized that 7T MRI direct targeting would be noninferior to 3T MRI in early tremor outcomes. METHODS A retrospective study was conducted on patients undergoing unilateral thalamic DBS for essential tremor between 2021 and 2023. Two matched cohorts were assessed, one using 7T MRI and the other using 3T MRI for surgical planning. The primary endpoint was the percentage improvement in the Fahn-Tolosa-Marin Tremor Rating Scale (TRS) scores. Additionally, the authors assessed optimized programming settings and variance in electrode position on postoperative imaging. Demographic and clinical data were compared using the nonparametric Mann-Whitney U-test. The squared Euclidean distance of each contact from the group mean centroid was calculated and averaged across the entire cohort to provide the variance (i.e., the mean squared distance) of electrode contact position. RESULTS A total of 34 patients were analyzed, with 17 in each cohort. There were no significant differences in demographic information or mean surgical dates between the groups. There were no differences in intraoperative target repositioning or adverse events. The 7T group had a significantly greater TRS improvement than the 3T group (64.9% ± 11.4% vs 50.9% ± 16.4%, p = 0.004). Patients in the 7T cohort also had a lower mean stimulation current compared with those in the 3T cohort (2.0 ± 0.8 mA vs 2.7 ± 0.9 mA, p = 0.01). Image evaluation revealed that although the mean electrode position was comparable between 7T and 3T, the 7T electrode positioning was more clustered, indicating a lower variance in the final electrode location. The mean Euclidean distance between the individual electrode tips and the group centroid was significantly less at 7T than at 3T (1.82 ± 0.68 mm vs 2.75 ± 0.81 mm, p = 0.001). CONCLUSIONS Despite concerns for increased artifacts and distortions at 7T, the authors show that these effects can be mitigated with an appropriate workflow, leading to improved surgical outcomes with direct targeting using 7T MRI. Their results suggest similar accuracy but greater precision in targeting with 7T MRI compared with 3T MRI, resulting in lower stimulation currents and improved tremor reduction. Future studies are needed to assess outcomes related to 7T MRI in targeting other subcortical structures.

Publisher

Journal of Neurosurgery Publishing Group (JNSPG)

Reference33 articles.

1. A comparison of indirect and direct targeted STN DBS in the treatment of Parkinson’s disease-surgical method and clinical outcome over 15-year timespan;Lahtinen MJ,2020

2. Clinical outcome of imaging-based programming for anterior thalamic nucleus deep brain stimulation;Freund BE,2022

3. Deep brain stimulation for tremor: direct targeting of a novel imaging biomarker;Middlebrooks EH,2022

4. Variability between direct and indirect targeting of the anterior nucleus of the thalamus;Grewal SS,2020

5. Personalizing deep brain stimulation using advanced imaging sequences;Neudorfer C,2022

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. A reproducible pipeline for parcellation of the anterior limb of the internal capsule;Biological Psychiatry: Cognitive Neuroscience and Neuroimaging;2024-07

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3