Affiliation:
1. Department of Neurologic Surgery and
2. IRCCS Institute of Neurological Sciences of Bologna, Division of Neurosurgery, Bellaria Hospital, Bologna, Italy
3. Evidence-Based Practice Center, Mayo Clinic, Rochester, Minnesota; and
Abstract
OBJECTIVEDifferent CSF diversion procedures (ventriculoperitoneal, ventriculoatrial, and lumboperitoneal shunting) have been utilized for the treatment of idiopathic normal pressure hydrocephalus. More recently, endoscopic third ventriculostomy has been suggested as a reasonable alternative in some studies. The purpose of this study was to perform a systematic review and meta-analysis to assess overall rates of favorable outcomes and adverse events for each of these treatments. An additional objective was to determine the outcomes and complication rates in relation to the type of valve utilized (fixed vs programmable).METHODSMultiple databases (PubMed, Ovid MEDLINE In-Process & Other Non-Indexed Citations, Ovid MEDLINE, Ovid Embase, Ovid Cochrane Central Register of Controlled Trials, Ovid Cochrane Database of Systematic Reviews, and Scopus) were searched for studies involving patients with idiopathic ventriculomegaly, no secondary cause of hydrocephalus, opening pressure < 25 mm Hg on high-volume tap or drainage trial, and age > 60 years. Outcomes included the proportion of patients who showed improvement in gait, cognition, and bladder function. Adverse events considered in the analysis included postoperative ischemic/hemorrhagic complications, subdural fluid collections, seizures, need for revision surgery, and infection.RESULTSA total of 33 studies, encompassing 2461 patients, were identified. More than 75% of patients experienced improvement after shunting, without significant differences among the different techniques utilized. Overall, gait improvement was observed in 75% of patients, cognitive function improvement in more than 60%, and improvement of incontinence in 55%. Adjustable valves were associated with a reduction in revisions (12% vs 32%) and subdural collections (9% vs 22%) as compared to fixed valves.CONCLUSIONSOutcomes did not differ significantly among different CSF diversion techniques, and overall improvement was reported in more than 75% of patients. The use of programmable valves decreased the incidence of revision surgery and of subdural collections after surgery, potentially justifying the higher initial cost associated with these valves.
Publisher
Journal of Neurosurgery Publishing Group (JNSPG)
Subject
Genetics,Animal Science and Zoology
Cited by
115 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献