Management of device-related wound complications in deep brain stimulation surgery

Author:

Fenoy Albert J.1,Simpson Richard K.2

Affiliation:

1. Mischer Neuroscience Institute, Department of Neurosurgery, University of Texas-Houston Health Science Center; and

2. Methodist Neurological Institute, Department of Neurosurgery, Houston, Texas

Abstract

Object Wound complications are uncommon following deep brain stimulation (DBS) surgery. However, certain key technical steps can be performed in each procedure to minimize this still troublesome risk. The authors reviewed the incidence and management of all hardware-related wound dehiscences and infections in a large patient series. Methods All patients undergoing new DBS hardware implantation surgery between 2002 and 2010 by a single surgeon (R.K.S.) were entered into a database after undergoing verification by cross-referencing manufacturer implantation records. All hardware-related complications such as wound dehiscence, erosions, and/or infections were identified, and wound location, time of incidence, and mechanism were categorized. Charts were reviewed to evaluate the success of conservative treatment versus partial or total hardware removal. Results Seven hundred twenty-eight patients received 1333 new DBS leads and 1218 new implantable pulse generators (IPGs) in a total of 1356 stereotactic procedures for movement disorders. Seventy-eight percent of patients underwent staged lead and IPG implantations. Sixteen patients presented with atraumatic device-related infection and/or dehiscence within 12 months from original implantation; 9 of these patients (1.24%) required additional surgery after antibiotic failure. All 8 patients presenting with cranial wound complications were treated initially by debridement in an attempt to salvage the leads; debridement followed by intravenous antibiotics was only successful in 2 patients presenting with dehiscence alone. One of 2 lead-only removals was successful in infections originating in the cranium; the only IPG-originating infection was treated by partial hardware removal and intravenous antibiotics. Two of 637 IPG replacements resulted in infections within 12 months after revision, requiring either partial or total hardware removal, while 1 dehiscence in this group was treated by debridement alone. Conclusions In a large series of new DBS hardware implantations, the incidence of postoperative wound dehiscence and/or infections requiring further surgery was 1.24%. Standard practice for all implantations was a short procedural duration, copious povidone-iodine irrigation, and postoperative antibiotic administration. Partial hardware removal should be initially attempted for infection. Debridement alone is successful in treating dehiscence without infection.

Publisher

Journal of Neurosurgery Publishing Group (JNSPG)

Subject

Genetics,Animal Science and Zoology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3