Pipeline embolization device for recurrence of previously treated aneurysms

Author:

Dornbos David,Karras Constantine L.,Wenger Nicole,Priddy Blake,Youssef Patrick,Nimjee Shahid M.,Powers Ciarán J.

Abstract

OBJECTIVEThe utilization of the Pipeline embolization device (PED) has increased significantly since its inception and original approval for use in large, broad-necked aneurysms of the internal carotid artery. While microsurgical clipping and advances in endovascular techniques have improved overall efficacy in achieving complete occlusion, recurrences still occur, and the best modality for retreatment remains controversial. Despite its efficacy in this setting, the role of PED utilization in the setting of recurrent aneurysms has not yet been well defined. This study was designed to assess the safety and efficacy of PED in the recurrence of previously treated aneurysms.METHODSThe authors reviewed a total of 13 cases in which patients underwent secondary placement of a PED for aneurysm recurrence following prior treatment with another modality. The PEDs were used to treat aneurysm recurrence or residual following endovascular coiling in 7 cases, flow diversion in 2, and microsurgical clipping in 4. The mean time between initial treatment and retreatment with a PED was 28.1 months, 12 months, and 88.7 months, respectively. Clinical outcomes, including complications and modified Rankin Scale (mRS) scores, and angiographic evidence of complete occlusion were tabulated for each treatment group.RESULTSAll PEDs were successfully placed without periprocedural complications. The rate of complete occlusion was 80% at 6 months after PED placement and 100% at 12 months in these patients who underwent PED placement following failed endovascular coiling; there were no adverse clinical sequelae at a mean follow-up of 26.1 months. In the 2 cases in which PEDs were placed for treatment of residual aneurysms following prior flow diversion, 1 patient demonstrated asymptomatic vessel occlusion at 6 months, and the other exhibited complete aneurysm occlusion at 12 months. In patients with aneurysm recurrence following prior microsurgical clipping, the rate of complete occlusion was 100% at 6 and 12 months, with no adverse sequelae noted at a mean clinical follow-up of 27.7 months.CONCLUSIONSThe treatment of recurrent aneurysms with the PED following previous endovascular coiling, flow diversion, or microsurgical clipping is associated with a high rate of complete occlusion and minimal morbidity.

Publisher

Journal of Neurosurgery Publishing Group (JNSPG)

Subject

Neurology (clinical),General Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3