A novel index for assessing treatment plan quality in stereotactic radiosurgery

Author:

Dimitriadis Alexis,Paddick Ian

Abstract

OBJECTIVEStereotactic radiosurgery (SRS) is characterized by high levels of conformity and steep dose gradients from the periphery of the target to surrounding tissue. Clinical studies have backed up the importance of these factors through evidence of symptomatic complications. Available data suggest that there are threshold doses above which the risk of symptomatic radionecrosis increases with the volume irradiated. Therefore, radiosurgical treatment plans should be optimized by minimizing dose to the surrounding tissue while maximizing dose to the target volume. Several metrics have been proposed to quantify radiosurgical plan quality, but all present certain weaknesses. To overcome limitations of the currently used metrics, a novel metric is proposed, the efficiency index (η50%), which is based on the principle of calculating integral doses: η50% = integral doseTV/integral dosePIV50%.METHODSThe value of η50% can be easily calculated by dividing the integral dose (mean dose × volume) to the target volume (TV) by the integral dose to the volume of 50% of the prescription isodose (PIV50%). Alternatively, differential dose-volume histograms (DVHs) of the TV and PIV50% can be used. The resulting η50% value is effectively the proportion of energy within the PIV50% that falls into the target. This value has theoretical limits of 0 and 1, with 1 being perfect. The index combines conformity, gradient, and mean dose to the target into a single value. The value of η50% was retrospectively calculated for 100 clinical SRS plans.RESULTSThe value of η50% for the 100 clinical SRS plans ranged from 37.7% to 58.0% with a mean value of 49.0%. This study also showed that the same principles used for the calculation of η50% can be adapted to produce an index suitable for multiple-target plans (Gη12Gy). Furthermore, the authors present another adaptation of the index that may play a role in plan optimization by calculating and minimizing the proportion of energy delivered to surrounding organs at risk (OARη50%).CONCLUSIONSThe proposed efficiency index is a novel approach in quantifying plan quality by combining conformity, gradient, and mean dose into a single value. It quantifies the ratio of the dose “doing good” versus the dose “doing harm,” and its adaptations can be used for multiple-target plan optimization and OAR sparing.

Publisher

Journal of Neurosurgery Publishing Group (JNSPG)

Subject

Genetics,Animal Science and Zoology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3