Abstract
OBJECTIVEIntraoperative neuromonitoring may be valuable for predicting postoperative neurological complications, and transcranial motor evoked potentials (TcMEPs) are the most reliable monitoring modality with high sensitivity. One of the most frequent problems of TcMEP monitoring is the high rate of false-positive alerts, also called “anesthetic fade.” The purpose of this study was to clarify the risk factors for false-positive TcMEP alerts and to find ways to reduce false-positive rates.METHODSThe authors analyzed 703 patients who underwent TcMEP monitoring under total intravenous anesthesia during spinal surgery within a 7-year interval. They defined an alert point as final TcMEP amplitudes ≤ 30% of the baseline. Variations in body temperature (maximum − minimum body temperature during surgery) were measured. Patients with false-positive alerts were classified into 2 groups: a global group with alerts observed in 2 or more muscles of the upper and lower extremities, and a focal group with alerts observed in 1 muscle.RESULTSFalse-positive alerts occurred in 100 cases (14%), comprising 60 cases with global and 40 cases with focal alerts. Compared with the 545 true-negative cases, in the false-positive cases the patients had received a significantly higher total propofol dose (1915 mg vs 1380 mg; p < 0.001). In the false-positive cases with global alerts, the patients had also received a higher mean propofol dose than those with focal alerts (4.5 mg/kg/hr vs 4.2 mg/kg/hr; p = 0.087). The cutoff value of the total propofol dose for predicting false-positive alerts, with the best sensitivity and specificity, was 1550 mg. Multivariate logistic analysis revealed that a total propofol dose > 1550 mg (OR 4.583; 95% CI 2.785–7.539; p < 0.001), variation in body temperature (1°C difference; OR 1.691; 95% CI 1.060–2.465; p < 0.01), and estimated blood loss (500-ml difference; OR 1.309; 95% CI 1.155–1.484; p < 0.001) were independently associated with false-positive alerts.CONCLUSIONSIntraoperative total propofol dose > 1550 mg, larger variation in body temperature, and greater blood loss are independently associated with false-positive alerts during spinal surgery. The authors believe that these factors may contribute to the false-positive global alerts that characterize anesthetic fade. As it is necessary to consider multiple confounding factors to distinguish false-positive alerts from true-positive alerts, including variation in body temperature or ischemic condition, the authors argue the importance of a team approach that includes surgeons, anesthesiologists, and medical engineers.
Publisher
Journal of Neurosurgery Publishing Group (JNSPG)
Reference62 articles.
1. Transcranial motor evoked potential waveform changes in corrective fusion for adolescent idiopathic scoliosis;Kobayashi;J Neurosurg Pediatr,2017
2. The efficacy of motor evoked potentials in fixed sagittal imbalance deformity correction surgery;LiebermanJA;Spine,1976
3. Intraoperative motor evoked potential monitoring—a position statement by the American Society of Neurophysiological Monitoring;Macdonald;Clin Neurophysiol,2013
4. Multimodal intraoperative monitoring during surgery of spinal deformities in patients;EggspuehlerA;Eur Spine J,2007
5. The evidence for intraoperative neurophysiological monitoring in spine does it make a difference;FehlingsMG;surgery Spine,1976
Cited by
28 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献