Radiosurgery for benign tumors of the spine using the Synergy S with cone-beam computed tomography image guidance

Author:

Gerszten Peter C.12,Chen Stephanie3,Quader Mubina2,Xu Yuanguang2,Novotny Josef245,Flickinger John C.12

Affiliation:

1. Departments of Neurological Surgery and

2. Radiation Oncology, University of Pittsburgh Medical Center;

3. University of Pittsburgh School of Medicine, Pittsburgh, Pennsylvania;

4. Department of Medical Physics, Na Homolce Hospital, Prague; and

5. Institute of Biophysics and Informatics, First Faculty of Medicine, Charles University in Prague, Czech Republic

Abstract

Object There is a growing body of evidence to support the safe and effective use of spine radiosurgery. However, there is much less experience regarding the use of radiosurgery for the treatment of benign as opposed to malignant spine tumors. This study represents an evaluation of, and reporting on, the technical aspects of using a dedicated radiosurgery system for the treatment of benign spine tumors. Methods Forty-five consecutive benign spine tumors were treated using the Elekta Synergy S 6-MV linear accelerator with a beam modulator and cone-beam computed tomography (CBCT) image guidance technology for target localization. The study cohort included 16 men and 29 women, ranging in age from 23 to 88 years (mean age 52 years). There were 14 cervical, 12 thoracic, 14 lumbar, and 5 sacral tumors. Forty-one lesions (91%) were intradural. The most common histological types of tumor were schwannoma, neurofibroma, and meningioma. Indications for radiosurgery included primary treatment in 24 cases (53%) and treatment of recurrent or residual tumor after open resection in 21 cases (47%). Results No subacute or long-term spinal cord or cauda equina toxicity occurred during the follow-up period (median 32 months). The mean maximum dose received by the gross tumor volume (GTV) was 16 Gy (range 12–24 Gy) delivered in a single fraction in 39 cases. The mean lowest dose received to the GTV was 12 Gy (range 8–16 Gy). The GTV ranged from 0.37 to 94.5 cm3 (mean 13.7 cm3, median 5.9 cm3). In the majority of cases, a planning target volume expansion of 2 mm was employed (38 cases; 84%). The mean maximum point dose delivered to the spinal cord was 8.7 Gy (range 4–11.5 Gy); the mean volume of the spinal cord that received greater than 8 Gy was 0.9 cm3 (range 0.0–5.1 cm3); and the mean dose delivered to 0.1 cm3 of the spinal cord was 7.5 Gy (range 3–10.5 Gy). The mean maximum point dose delivered to the cauda equina was 10 Gy (range 0–13 Gy); the mean volume of the cauda equina that received greater than 8 Gy was 1.45 cm3 (range 0.0–10.6 cm3); and the mean dose delivered to 0.1 cm3 of the cauda equina was 8 Gy (range 0.5–11 Gy). Conclusions In this study the authors describe the contouring and prescribed dose techniques used in the treatment planning and delivery of radiosurgery for benign neoplasms of the spine using CBCT image guidance. This technique may serve as an important reference for the performance of radiosurgery when one believes it is clinically indicated as a treatment modality for a benign spine tumor that is associated with both a high safety profile and a strong positive clinical outcome.

Publisher

Journal of Neurosurgery Publishing Group (JNSPG)

Subject

Genetics,Animal Science and Zoology

Cited by 27 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3