Gait-simulating fatigue loading analysis and sagittal alignment failure of spinal pelvic reconstruction after total sacrectomy: comparison of 3 techniques

Author:

Clark Aaron J.1,Tang Jessica A.1,Leasure Jeremi M.23,Ivan Michael E.1,Kondrashov Dimitriy34,Buckley Jenni M.25,Deviren Vedat6,Ames Christopher P.1

Affiliation:

1. 1Departments of Neurological Surgery and

2. 3The Taylor Collaboration Laboratories, San Francisco;

3. 4San Francisco Orthopaedic Residency Program, San Francisco;

4. 6St. Mary's Spine Center, San Francisco, California; and

5. 5Department of Mechanical Engineering, University of Delaware, Newark, Delaware

6. 2Orthopaedic Surgery, University of California, San Francisco;

Abstract

Object Reconstruction after total sacrectomy is a critical component of malignant sacral tumor resection, permitting early mobilization and maintenance of spinal pelvic alignment. However, implant loosening, graft migration, and instrumentation breakage remain major problems. Traditional techniques have used interiliac femoral allograft, but more modern methods have used fibular or cage struts from the ilium to the L-5 endplate or sacral body replacement with transiliac bars anchored to cages to the L-5 endplate. This study compares the biomechanical stability under gait-simulating fatigue loading of the 3 current methods. Methods Total sacrectomy was performed and reconstruction was completed using 3 different constructs in conjunction with posterior spinal screw rod instrumentation from L-3 to pelvis: interiliac femur strut allograft (FSA); L5–iliac cage struts (CSs); and S-1 body replacement expandable cage (EC). Intact lumbar specimens (L3–sacrum) were tested for flexion-extension range of motion (FE-ROM), axial rotation ROM (AX-ROM), and lateral bending ROM (LB-ROM). Each instrumented specimen was compared with its matched intact specimen to generate an ROM ratio. Fatigue testing in compression and flexion was performed using a custom-designed long fusion gait model. Results Compared with intact specimen, the FSA FE-ROM ratio was 1.22 ± 0.60, the CS FE-ROM ratio was significantly lower (0.37 ± 0.12, p < 0.001), and EC was lower still (0.29 ± 0.14, p < 0.001; values are expressed as the mean ± SD). The difference between CS and EC in FE-ROM ratio was not significant (p = 0.83). There were no differences in AX-ROM or LB-ROM ratios (p = 0.77 and 0.44, respectively). No failures were noted on fatigue testing of any EC construct (250,000 cycles). This was significantly improved compared with FSA (856 cycles, p < 0.001) and CS (794 cycles, p < 0.001). Conclusions The CS and EC appear to be significantly more stable constructs compared with FSA with FE-ROM. The 3 constructs appear to be equal with AX-ROM and LB-ROM. Most importantly, EC appears to be significantly more resistant to fatigue compared with FSA and CS. Reconstruction of the load transfer mechanism to the pelvis via the L-5 endplate appears to be important in maintenance of alignment after total sacrectomy reconstruction.

Publisher

Journal of Neurosurgery Publishing Group (JNSPG)

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3