Efficacy and safety of a collagen matrix for cranial and spinal dural reconstruction using different fixation techniques

Author:

Stendel Ruediger1,Danne Marco1,Fiss Ingo1,Klein Ilse1,Schilling Andreas2,Hammersen Stefanie1,Pietilae Terttu1,Jänisch Werner3,Hopfenmüller Werner4

Affiliation:

1. Departments of Neurosurgery and

2. Radiology and Nuclear Medicine,

3. Institute of Neuropathology; and

4. Institute for Biometrics and Clinical Epidemiology, Charité–Universitätsmedizin Berlin, Campus Benjamin Franklin, Berlin, Germany

Abstract

Object The use of dural grafts is frequently unavoidable when tension-free dural closure cannot be achieved following neurosurgical procedures or trauma. Biodegradable collagen matrices serve as a scaffold for the regrowth of natural tissue and require no suturing. The aim of this study was to investigate the efficacy and safety of dural repair with a collagen matrix using different fixation techniques. Methods A total of 221 patients (98 male and 123 female; mean age 55.6 ± 17.8 years) undergoing cranial (86.4%) or spinal (13.6%) procedures with the use of a collagen matrix dural graft were included in this retrospective study. The indications for use, fixation techniques, and associated complications were recorded. Results There were no complications of the dural graft in spinal use. Five (2.6%) of 191 patients undergoing cranial procedures developed infections, 3 of which (1.6%) were deep infections requiring surgical revision. There was no statistically significant relationship between the operative field status before surgery and the occurrence of a postoperative wound infection (p = 0.684). In the 191 patients undergoing a cranial procedure, cerebrospinal fluid (CSF) collection occurred in 5 patients (2.6%) and a CSF fistula in 5 (2.6%), 3 of whom (1.6%) required surgical revision. No patient who underwent an operation with preexisting CSF leakage had postoperative CSF leakage. Postoperative infection significantly increased the risk for postoperative CSF leakage. The collagen matrix was used without additional fixation in 124 patients (56.1%), with single fixation in 55 (24.9%), and with multiple fixations in 42 (19%). There were no systemic allergic reactions or local skin changes. Follow-up imaging in 112 patients (50.7%) revealed no evidence of any adverse reaction to the collagen graft. Conclusions The collagen matrix is an effective and safe cranial and spinal dural substitute that can be used even in cases of an existing local infection. Postoperative deep infection increases the risk for CSF leakage.

Publisher

Journal of Neurosurgery Publishing Group (JNSPG)

Subject

Genetics,Animal Science and Zoology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3