Dosimetric comparison of the Leksell Gamma Knife Perfexion and 4C

Author:

Novotny Josef1,Bhatnagar Jagdish P.1,Niranjan Ajay2,Quader Mubina A.1,Huq M. Saiful1,Bednarz Greg1,Flickinger John C.1,Kondziolka Douglas2,Lunsford L. Dade2

Affiliation:

1. Department of Radiation Oncology, University of Pittsburgh Cancer Institute; and

2. Department of Neurological Surgery, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania

Abstract

Object The recently introduced Leksell Gamma Knife (LGK) Perfexion is an entirely new system with a different beam geometry compared with the LGK 4C. The new Perfexion system has 192 cobalt-60 sources that are fixed on 8 sectors (each sector has 24 sources). Each sector can be moved independently of the others and can be set to 1 of 5 different positions: 3 positions defining collimator sizes of 4, 8, and 16 mm; an off position (sources are blocked); and a home position. The purpose of this study is to compare the dosimetric characteristics of the GK 4C and the Perfexion models. This comparison is important especially for the treatment of functional disorders when only a single shot with the 4- or 8-mm collimator is used. Methods A 160-mm-diameter spherical polystyrene phantom was used for all measurements and calculations. The irradiation geometry consisted of the placement of a single shot at the center of this phantom. Comparisons were made among different dosimetric parameters obtained from calculations performed using Leksell GammaPlan v. 8.0 and measurements performed using film dosimetry. The dosimetric parameters investigated were dose profiles for all collimators in all 3 stereotactic planes (x, y, and z) including the full width at half maximum and the penumbra for each profile, cumulative dose–volume histograms, the volume encompassed by the 50% isodose surface, the mean doses delivered to a defined matrix volume, and relative output factors for all collimator sizes. Results There was excellent agreement between the dosimetric parameters of GK 4C and Perfexion for the 4- and 8-mm collimators. Conclusions The results of this study suggest that consistent treatments of functional disorders will be delivered using either GK 4C or Perfexion.

Publisher

Journal of Neurosurgery Publishing Group (JNSPG)

Subject

Genetics,Animal Science and Zoology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3