Image registration accuracy of GammaPlan: a phantom study

Author:

Watanabe Yoichi1,Han Eunyoung2

Affiliation:

1. Department of Therapeutic Radiology, University of Minnesota, Minneapolis, Minnesota; and

2. Radiation Oncology Department, Berkshire Medical Center, Pittsfield, Massachusetts

Abstract

Object The authors evaluated the accuracy of the automatic image coregistration function implemented in the Leksell GammaPlan treatment planning software (Version 4C with MultiView Extension and Version 8.0). Methods The authors used a phantom with 9 landmarks (tips of thin cylindrical acrylic rods) evenly distributed in the treatment space. Two sets of images of the phantom were taken with both CT and MR imaging systems. The first image was obtained with the phantom aligned with the scanner's axis and the second scan was made by intentionally shifting and rotating the phantom relative to the scanner's axis. The authors attempted image registration of 2 CT image sets, CT and MR image sets, and 2 MR image sets. The accuracy of image registration was evaluated by measuring the x, y, and z coordinate values of the landmarks on each image set after 2 image sets were coregistered. The authors calculated the differences of the x, y, and z values and the distance, d, between corresponding landmarks in 2 image sets. To minimize interobserver dependence of coordinate measurements, 2 physicists did measurements independently. Results The distances, d, averaged over the 9 landmarks, were 2.63 ± 1.64 and 0.95 ± 0.25 mm for CT–CT and MR–MR image registrations, respectively. When the CT images of the air-filled phantom and MR images were coregistered, however, the algorithm performed poorly: d = 13.8 ± 1.23 mm. To remedy this, the authors undertook a 2-step process by first performing landmark-based registration of the 2 image sets and subsequently applying the automatic registration. With this approach, the mean distance drastically improved: d = 0.74 ± 0.31 mm. When the water-filled phantom was used for CT scans, the registration accuracy of CT and MR image sets was acceptable without the 2-step registration process: d = 1.18 ± 0.36 mm. Conclusions The accuracy of automatic registration of image sets from the same modality was within the voxel size of the scanned images. The accuracy of CT–MR image registration strongly depended on whether the phantom for CT scans was filled with air or water. This indicates the significant effect of the amount of common data available for a mutual information-based algorithm on the accuracy.

Publisher

Journal of Neurosurgery Publishing Group (JNSPG)

Subject

Genetics,Animal Science and Zoology

Cited by 16 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3