Novel experimental surgical strategy to prevent traumatic neuroma formation by combining a 3D-printed Y-tube with an autograft

Author:

Bolleboom Anne12,de Ruiter Godard C. W.3,Coert J. Henk4,Tuk Bastiaan2,Holstege Jan C.1,van Neck Johan W.2

Affiliation:

1. Departments of Neuroscience, and

2. Plastic and Reconstructive Surgery, Erasmus University Medical Center, Rotterdam;

3. Department of Neurosurgery, Medical Center Haaglanden, The Hague; and

4. Department of Plastic and Reconstructive Surgery, Utrecht University Medical Center, Utrecht, The Netherlands

Abstract

OBJECTIVETraumatic neuromas may develop after nerve injury at the proximal nerve stump, which can lead to neuropathic pain. These neuromas are often resistant to therapy, and excision of the neuroma frequently leads to recurrence. In this study, the authors present a novel surgical strategy to prevent neuroma formation based on the principle of centro-central anastomosis (CCA), but rather than directly connecting the nerve ends to an autograft, they created a loop using a 3D-printed polyethylene Y-shaped conduit with an autograft in the distal outlets.METHODSThe 3D-printed Y-tube with autograft was investigated in a model of rat sciatic nerve transection in which the Y-tube was placed on the proximal sciatic nerve stump and a peroneal graft was placed between the distal outlets of the Y-tube to form a closed loop. This model was compared with a CCA model, in which a loop was created between the proximal tibial and peroneal nerves with a peroneal autograft. Additional control groups consisted of the closed Y-tube and the extended-arm Y-tube. Results were analyzed at 12 weeks of survival using nerve morphometry for the occurrence of neuroma formation and axonal regeneration in plastic semi-thin sections.RESULTSAmong the different surgical groups, the Y-tube with interposed autograft was the only model that did not result in neuroma formation at 12 weeks of survival. In addition, a 13% reduction in the number of myelinated axons regenerating through the interposed autograft was observed in the Y-tube with autograft model. In the CCA model, the authors also observed a decrease of 17% in the number of myelinated axons, but neuroma formation was present in this model. The closed Y-tube resulted in minimal nerve regeneration inside the tube together with extensive neuroma formation before the entrance of the tube. The extended-arm Y-tube model clearly showed that the majority of the regenerating axons merged into the Y-tube arm, which was connected to the autograft, leaving the extended plastic arm almost empty.CONCLUSIONSThis pilot study shows that our novel 3D-printed Y-tube model with interposed autograft prevents neuroma formation, making this a promising surgical tool for the management of traumatic neuromas.

Publisher

Journal of Neurosurgery Publishing Group (JNSPG)

Subject

Genetics,Animal Science and Zoology

Cited by 15 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3