Intraoperative monitoring with visual evoked potentials for brain surgeries

Author:

Gutzwiller Eveline M.1,Cabrilo Ivan1,Radovanovic Ivan2,Schaller Karl1,Boëx Colette3

Affiliation:

1. Departments of Neurosurgery and

2. Division of Neurosurgery, Toronto Western Hospitals, Krembil Neuroscience Center, University Health Network and University of Toronto, Ontario, Canada

3. Neurology, Geneva University Hospitals and Faculty of Medicine, Geneva, Switzerland; and

Abstract

OBJECTIVEThe goal of this study was to determine the performance of intraoperative visual evoked potentials (VEPs) in detecting visual field changes.METHODSAssessments of VEPs were performed with simultaneous retinal responses by using white light-emitting diodes protected from scialytic microscope lights. The alarm criterion was a reproducible decrease in amplitude of the VEP P100 wave of 20% or more. Visual fields were assessed preoperatively and 1 month postsurgery (Goldmann perimetry).RESULTSThe VEPs were analyzed for 29 patients undergoing resection of a brain lesion. In 89.7% of patients, steady VEP and retinal responses were obtained for monitoring. The absence of alarm was associated in 94.4% of cases with the absence of postoperative visual changes (specificity). The alarms correctly identified 66.7% of cases with any postoperative changes and 100% of cases with changes more severe than just a discrete quadrantanopia or deterioration of an existing quadrantanopia (sensitivity, new diffuse deterioration < 2 dB). In 11.5% of patients, a transitory VEP decrease with subsequent recovery was observed without postoperative defects.CONCLUSIONSIntraoperative VEPs were performed with simultaneous recording of electroretinograms, with protection from lights of the operating room and with white light-emitting diodes. Intraoperative VEPs were shown to be reliable in predicting postoperative visual field changes. In this series of intraaxial brain procedures, reliable intraoperative VEP monitoring was achieved, allowing at minimum the detection of new quadrantanopia. The standardization of this technique appears to be a valuable effort in regard to the functional risks of homonymous hemianopia.

Publisher

Journal of Neurosurgery Publishing Group (JNSPG)

Subject

Genetics,Animal Science and Zoology

Cited by 49 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3