A novel pressure sensor with an optical system for coil embolization of intracranial aneurysms

Author:

Matsubara Noriaki1,Miyachi Shigeru1,Nagano Yoshitaka23,Ohshima Tomotaka1,Hososhima Osamu1,Izumi Takashi1,Tsurumi Arihito1,Wakabayashi Toshihiko1,Sakaguchi Masamichi2,Sano Akihito2,Fujimoto Hideo2

Affiliation:

1. Department of Neurosurgery, Nagoya University Graduate School of Medicine;

2. Graduate School of Engineering, Nagoya Institute of Technology, Nagoya, Aichi; and

3. New Product Development R&D Center, NTN Corporation, Iwata, Shizuoka, Japan

Abstract

Object In endovascular coil embolization for an intracranial aneurysm, the excessive pressure created during coil insertion into an aneurysm can cause a catastrophic rupture or dislodge a microcatheter tip from the aneurysm dome, resulting in insufficient embolization. Such undue mechanical pressure can only be subjectively detected by the subtle tactile feedback the surgeon experiences. Therefore, the authors of this study developed a new sensor device to measure the coil insertion pressure via an optical system. Methods This novel sensor system consists of a hemostatic valve connected to the proximal end of a microcatheter (Y-connector). The sensor principle is based on an optical system composed of a light-emitting diode (LED) and a line sensor. The latter measures how much the coil-delivery wire slightly bends in response to the insertion pressure by detecting the wire shadow. This information is translated into a given force level. Experimental aneurysm embolization was performed using this optical sensor. A silicone aneurysm model and an in vivo model (porcine aneurysm model) were used in this study. Several surgeons manually performed the coil insertions. The sensor continuously monitored the mechanical force during the insertions. Results The sensor adequately recorded the coil insertion pressure during embolization. The presence of the sensor did not hinder the embolization procedure in any way. During embolization in the silicone aneurysm model, a sinusoid pattern of pressure occurred, reflecting actual clinical experience. Similar results were obtained in the in vivo study. Conclusions This new sensor device adequately measures coil insertion pressure. This system provides potentially safer and more reliable aneurysm embolizations.

Publisher

Journal of Neurosurgery Publishing Group (JNSPG)

Subject

Genetics,Animal Science and Zoology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3