Deep brain stimulation hardware–related infections: 10-year experience at a single institution

Author:

Abode-Iyamah Kingsley O.1,Chiang Hsiu-Yin2,Woodroffe Royce W.1,Park Brian1,Jareczek Francis J.3,Nagahama Yasunori1,Winslow Nolan3,Herwaldt Loreen A.245,Greenlee Jeremy D. W.1

Affiliation:

1. Departments of Neurosurgery and

2. Internal Medicine,

3. University of Iowa Carver College of Medicine;

4. Program of Hospital Epidemiology, University of Iowa Hospitals and Clinics; and

5. Department of Epidemiology, University of Iowa College of Public Health, Iowa City, Iowa

Abstract

OBJECTIVEDeep brain stimulation is an effective surgical treatment for managing some neurological and psychiatric disorders. Infection related to the deep brain stimulator (DBS) hardware causes significant morbidity: hardware explantation may be required; initial disease symptoms such as tremor, rigidity, and bradykinesia may recur; and the medication requirements for adequate disease management may increase. These morbidities are of particular concern given that published DBS-related infection rates have been as high as 23%. To date, however, the key risk factors for and the potential preventive measures against these infections remain largely uncharacterized. In this study, the authors endeavored to identify possible risk factors for DBS-related infection and analyze the efficacy of prophylactic intrawound vancomycin powder (VP).METHODSThe authors performed a retrospective cohort study of patients who had undergone primary DBS implantation at a single institution in the period from December 2005 through September 2015 to identify possible risk factors for surgical site infection (SSI) and to assess the impact of perioperative (before, during, and after surgery) prophylactic antibiotics on the SSI rate. They also evaluated the effect of a change in the National Healthcare Safety Network’s definition of SSI on the number of infections detected. Statistical analyses were performed using the 2-sample t-test, the Wilcoxon rank-sum test, the chi-square test, Fisher’s exact test, or logistic regression, as appropriate for the variables examined.RESULTSFour hundred sixty-four electrodes were placed in 242 adults during 245 primary procedures over approximately 10.5 years; most patients underwent bilateral electrode implantation. Among the 245 procedures, 9 SSIs (3.7%) occurred within 90 days and 16 (6.5%) occurred within 1 year of DBS placement. Gram-positive bacteria were the most common etiological agents. Most patient- and procedure-related characteristics did not differ between those who had acquired an SSI and those who had not. The rate of SSIs among patients who had received intrawound VP was only 3.3% compared with 9.7% among those who had not received topical VP (OR 0.32, 95% CI 0.10–1.02, p = 0.04). After controlling for patient sex, the association between VP and decreased SSI risk did not reach the predetermined level of significance (adjusted OR 0.32, 95% CI 0.10–1.03, p = 0.06). The SSI rates were similar after staged and unstaged implantations.CONCLUSIONSWhile most patient-related and procedure-related factors assessed in this study were not associated with the risk for an SSI, the data did suggest that intrawound VP may help to reduce the SSI risk after DBS implantation. Furthermore, given the implications of SSI after DBS surgery and the frequency of infections occurring more than 90 days after implantation, continued follow-up for at least 1 year after such a procedure is prudent to establish the true burden of these infections and to properly treat them when they do occur.

Publisher

Journal of Neurosurgery Publishing Group (JNSPG)

Subject

Genetics,Animal Science and Zoology

Cited by 57 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3