The accuracy of pedicle screw placement using intraoperative image guidance systems

Author:

Mason Alexander12,Paulsen Renee1,Babuska Jason M.1,Rajpal Sharad2,Burneikiene Sigita12,Nelson E. Lee12,Villavicencio Alan T.12

Affiliation:

1. 1Justin Parker Neurological Institute, and

2. 2Boulder Neurosurgical Associates, Boulder, Colorado

Abstract

Object Several retrospective studies have demonstrated higher accuracy rates and increased safety for navigated pedicle screw placement than for free-hand techniques; however, the accuracy differences between navigation systems has not been extensively studied. In some instances, 3D fluoroscopic navigation methods have been reported to not be more accurate than 2D navigation methods for pedicle screw placement. The authors of this study endeavored to identify if 3D fluoroscopic navigation methods resulted in a higher placement accuracy of pedicle screws. Methods A systematic analysis was conducted to examine pedicle screw insertion accuracy based on the use of 2D, 3D, and conventional fluoroscopic image guidance systems. A PubMed and MEDLINE database search was conducted to review the published literature that focused on the accuracy of pedicle screw placement using intraoperative, real-time fluoroscopic image guidance in spine fusion surgeries. The pedicle screw accuracy rates were segregated according to spinal level because each spinal region has individual anatomical and morphological variations. Descriptive statistics were used to compare the pedicle screw insertion accuracy rate differences among the navigation methods. Results A total of 30 studies were included in the analysis. The data were abstracted and analyzed for the following groups: 12 data sets that used conventional fluoroscopy, 8 data sets that used 2D fluoroscopic navigation, and 20 data sets that used 3D fluoroscopic navigation. These studies included 1973 patients in whom 9310 pedicle screws were inserted. With conventional fluoroscopy, 2532 of 3719 screws were inserted accurately (68.1% accuracy); with 2D fluoroscopic navigation, 1031 of 1223 screws were inserted accurately (84.3% accuracy); and with 3D fluoroscopic navigation, 4170 of 4368 screws were inserted accurately (95.5% accuracy). The accuracy rates when 3D was compared with 2D fluoroscopic navigation were also consistently higher throughout all individual spinal levels. Conclusions Three-dimensional fluoroscopic image guidance systems demonstrated a significantly higher pedicle screw placement accuracy than conventional fluoroscopy or 2D fluoroscopic image guidance methods.

Publisher

Journal of Neurosurgery Publishing Group (JNSPG)

Subject

General Medicine

Cited by 296 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3