Delayed periprosthetic collection after cervical disc arthroplasty

Author:

Harris Lauren1,Dyson Edward1,Elliot Matthew1,Peterson David1,Ulbricht Christian1,Casey Adrian2

Affiliation:

1. Department of Neurosurgery, Imperial College Healthcare NHS Trust, Charing Cross Hospital, London, United Kingdom; and

2. Department of Neurosurgery, The National Hospital for Neurology and Neurosurgery, Queen Square, London, United Kingdom

Abstract

Cervical disc arthroplasty is a treatment option for symptomatic cervical disc disease. There is a paucity of literature on long-term safety outcomes, durability, and device-related failure rates. The M6-C artificial cervical disc is a device with titanium alloy endplates and a complex polymeric centerpiece. To date, trials have exhibited acceptable safety profiles.This case series describes the presentation, management, and pathological findings of a delayed prevertebral periprosthetic mass anterior to the M6-C disc. Four patients at 3 different institutions underwent cervical disc replacement with the M6-C disc. Two to seven years postoperatively, they presented with dysphagia secondary to a compressive mass anterior to the disc. Case notes were reviewed to collect data on symptoms, management, and outcomes. The patients were systemically well and presented with progressive dysphagia. They had imaging findings of a mass anterior to the disc. They underwent a decompressive procedure, with 2 patients undergoing device removal and fusion. In 2 cases, a soft-tissue mass was seen intraoperatively, with frank pus. In 3 cases, Propionibacterium acnes was identified and antibiotic treatment given. Histopathology demonstrated mixed inflammatory infiltrates with foreign body–type granulomas. Postoperatively, the dysphagia resolved.The development of delayed dysphagia in a patient with an M6-C disc should prompt investigation to identify a mass lesion. To the authors’ knowledge, this is the first report of delayed infection, or suspected delayed-type hypersensitivity reaction, following M6-C disc implantation. It is important for this to be added to the device safety concerns. Further prospective studies are needed to establish the incidence and the long-term safety and failure rates of the M6-C disc.

Publisher

Journal of Neurosurgery Publishing Group (JNSPG)

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3