Targeted fascicular biopsy of the sciatic nerve and its major branches: rationale and operative technique

Author:

Capek Stepan12,Amrami Kimberly K.3,Dyck P. James B.4,Spinner Robert J.1

Affiliation:

1. Departments of Neurosurgery,

2. International Clinical Research Center, St. Anne’s University Hospital Brno, Brno, Czech Republic

3. Radiology, and

4. Neurology, Mayo Clinic, Rochester, Minnesota; and

Abstract

OBJECT Nerve biopsy is typically performed in distal, noncritical sensory nerves without using imaging to target the more involved regions. The yield of these procedures rarely achieves more than 50%. In selected cases where preoperative evaluation points toward a more localized (usually a more proximal) process, targeted biopsy would likely capture the disease. Synthesis of data obtained from clinical examination, electrophysiological testing, and MRI allows biopsy of a portion of the major mixed nerves safely and efficiently. Herein, experiences with the sciatic nerve are reported and a description of the operative technique is provided. METHODS All cases of sciatic nerve biopsy performed between 2000 and 2014 were reviewed. Only cases of fascicular nerve biopsy approached from the buttock or the posterior aspect of the thigh were included. Demographic data, clinical presentation, and the presence of percussion tenderness for each patient were recorded. Reviewed studies included electrodiagnostic tests and imaging. Previous nerve and muscle biopsies were noted. All details of the procedure, final pathology, and its treatment implications were recorded. The complication rate was carefully assessed for temporary as well as permanent complications. RESULTS One hundred twelve cases (63 men and 49 women) of sciatic nerve biopsy were performed. Mean patient age was 46.4 years. Seventy-seven (68.8%) patients presented with single lower-extremity symptoms, 16 (14.3%) with bilateral lower-extremity symptoms, and 19 (17%) with generalized symptoms. No patient had normal findings on physical examination. All patients underwent electrodiagnostic studies, the findings of which were abnormal in 110 (98.2%) patients. MRI was available for all patients and was read as pathological in 111 (99.1%). The overall diagnostic yield of biopsy was 84.8% (n = 95). The pathological diagnoses included inflammatory demyelination, perineurioma, nonspecific inflammatory changes, neurolymphomatosis, amyloidosis, prostate cancer, injury neuroma, neuromuscular choristoma, sarcoidosis, vasculitis, hemangiomatosis, arteriovenous malformation, fibrolipomatous hamartoma (lipomatosis of nerve), and cervical adenocarcinoma. The series included 11 (9.9%) temporary and 5 (4.5%) permanent complications: 3 patients (2.7%) reported permanent numbness in the peroneal division distribution, and 2 patients (1.8%) were diagnosed with neuromuscular choristoma that developed desmoid tumor at the biopsy site 3 and 8 years later. CONCLUSIONS Targeted fascicular biopsy of the sciatic nerve is a safe and efficient diagnostic procedure, and in highly selected cases can be offered as the initial procedure over distal cutaneous nerve biopsy. Diagnoses were very diverse and included entities considered very rare. Even for the more prevalent diagnoses, the biopsy technique allowed a more targeted approach with a higher diagnostic yield and justification for more aggressive treatment. In this series, new radiological patterns of some entities were identified, which could be biopsied less frequently.

Publisher

Journal of Neurosurgery Publishing Group (JNSPG)

Subject

Neurology (clinical),General Medicine,Surgery

Cited by 28 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3