Noncontrast vestibular schwannoma surveillance imaging including an MR cisternographic sequence: is there a need for postcontrast imaging?

Author:

Buch Karen1,Juliano Amy2,Stankovic Konstantina M.3,Curtin Hugh D.2,Cunnane Mary Beth2

Affiliation:

1. Department of Neuroradiology, Massachusetts General Hospital; and

2. Departments of Radiology and

3. Otolaryngology, Massachusetts Eye & Ear Infirmary, Boston, Massachusetts

Abstract

OBJECTIVEThe purpose of this study was to evaluate the use of a noncontrast MRI protocol that includes a cisternographic sequence (CISS/FIESTA/3D DRIVE) compared to a protocol that includes a gadolinium-enhanced sequence in order to determine whether a noncontrast approach could be utilized to follow vestibular schwannomas.METHODSA total of 251 patients with vestibular schwannomas who underwent MRI of the temporal bones that included both cisternographic sequence and postcontrast T1 imaging between January 2000 and January 2016 for surveillance were included in this retrospective study. The size of the vestibular schwannomas was independently assessed on a noncontrast MR cisternographic sequence and compared to size measurements on a postcontrast sequence. The evaluation of intralesional cystic components (identified as T2 signal hyperintensity) and hemorrhagic components (identified with intrinsic T1 hyperintensity) on noncontrast MR sequences was compared to evaluation on postcontrast MR sequences to determine whether additional information could be derived from the postcontrast sequences. Additionally, any potentially clinically significant, incidentally detected findings on the postcontrast T1 sequences were documented and compared with the detection of these findings on the precontrast images.RESULTSNo significant difference in vestibular schwannoma size was found when comparing measurements made on the images obtained with the MR cisternographic sequence and those made on images obtained with the postcontrast sequence (p = 0.99). Noncontrast MR images were better (detection rate of 87%) than postcontrast images for detection of cystic components. Noncontrast MR images were also better for identifying hemorrhagic components. No additional clinically relevant information regarding the tumors was identified on the postcontrast sequences.CONCLUSIONSBased on the results of this study, a noncontrast MR protocol that includes a cisternographic sequence would be sufficient for the accurate characterization of size and signal characteristics of vestibular schwannomas, obviating the need for gadolinium contrast administration for the routine surveillance of these lesions.

Publisher

Journal of Neurosurgery Publishing Group (JNSPG)

Subject

Genetics,Animal Science and Zoology

Reference50 articles.

1. Determinants of tumor size and growth in vestibular schwannomas;Nutik;J Neurosurg,2001

2. Diagnostic accuracy of screening MR imaging using unenhanced axial CISS and coronal T2WI for detection of small internal auditory canal lesions;Abele;AJNR Am J Neuroradiol,2014

3. Quantitative assessment of gadolinium deposition in dentate nucleus using quantitative susceptibility mapping;Hinoda;J Magn Reson Imaging,2017

4. Low-cost high-resolution fast spin-echo MR of acoustic schwannoma: an alternative to enhanced conventional spin-echo MR?;Allen;AJNR Am J Neuroradiol,1996

5. Conservative management of vestibular schwannoma: expectations based on the length of the observation period;Fayad;Otol Neurotol,2014

Cited by 15 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3