Author:
Rivkin Mark A.,Yocom Steven S.
Abstract
Object
Thoracolumbar instrumentation has experienced a dramatic increase in utilization over the last 2 decades. However, pedicle screw fixation remains a challenging undertaking, with suboptimal placement contributing to postoperative pain, neurological deficit, vascular complications, and return to the operating suite. Image-guided spinal surgery has substantially improved the accuracy rates for these procedures. However, it is not without technical challenges and a learning curve for novice operators. The authors present their experience with the O-arm intraoperative imaging system and share the lessons they learned over nearly 5 years.
Methods
The authors performed a retrospective chart review of 270 consecutive patients who underwent thoracolumbar pedicle screw fixation utilizing the O-arm imaging system in conjunction with StealthStation navigation between April 2009 and September 2013 at a single tertiary care center; 266 of the patients underwent CT scanning on postoperative Day 1 to evaluate hardware placement. The CT scans were interpreted prospectively by 3 neuroradiologists as part of standard work flow and retrospectively by 2 neurosurgeons and a senior resident. Pedicle screws were evaluated for breaches according to the 3-tier classification proposed by Mirza et al.
Results
Of 270 patients, 266 (98.5%) were included in the final analysis based on the presence of a postoperative CT scan. Overall, 1651 pedicle screws were placed in 266 patients and yielded a 5.3% breach rate; 213 thoracic and 1438 lumbosacral pedicle screws were inserted with 6.6% and 5.1% breach rates, respectively. Of the 87 suboptimally placed screws, there were 13 Grade 1, 16 Grade 2, and 12 Grade 3 misses as well as 46 anterolateral or “tip-out” perforations at L-5. Four patients (1.5%) required a return to the operating room for pedicle screw revision, 2 of whom experienced transient radicular symptoms and 2 remained asymptomatic. Interestingly, the pedicle breach rate was higher than anticipated at 13.21% for the 30 patients over the initial 6-month period with the O-arm. After certain modifications to the authors' technique, the subsequent 30 patients experienced a statistically significant decrease in breach rate at 5.6% (p = 0.014).
Conclusions
Image-guided spinal surgery can be a great option in the operating room and provides high pedicle screw accuracy rates. With numerous systems commercially available, it is important to develop a systematic approach regardless of the technology in question. There is a learning curve for surgeons unfamiliar with image guidance that should be recognized and appreciated when transitioning to navigation-assisted spinal surgery. In fact, the authors' experience with a large patient cohort suggests that this learning curve may be more significant than previously reported.
Publisher
Journal of Neurosurgery Publishing Group (JNSPG)
Subject
Neurology (clinical),General Medicine,Surgery
Cited by
85 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献