Transcranial magnetic resonance–guided focused ultrasound for temporal lobe epilepsy: a laboratory feasibility study

Author:

Monteith Stephen1,Snell John2,Eames Mathew2,Kassell Neal F.3,Kelly Edward2,Gwinn Ryder1

Affiliation:

1. Department of Neurosurgery, Swedish Neuroscience Institute, Seattle, Washington;

2. Focused Ultrasound Foundation, Charlottesville; and

3. Department of Neurosurgery, University of Virginia, Charlottesville, Virginia

Abstract

OBJECTIVE In appropriate candidates, the treatment of medication-refractory mesial temporal lobe epilepsy (MTLE) is primarily surgical. Traditional anterior temporal lobectomy yields seizure-free rates of 60%–70% and possibly higher. The field of magnetic resonance–guided focused ultrasound (MRgFUS) is an evolving field in neurosurgery. There is potential to treat MTLE with MRgFUS; however, it has appeared that the temporal lobe structures were beyond the existing treatment envelope of currently available clinical systems. The purpose of this study was to determine whether lesional temperatures can be achieved in the target tissue and to assess potential safety concerns. METHODS Cadaveric skulls with tissue-mimicking gels were used as phantom targets. An ablative volume was then mapped out for a “virtual temporal lobectomy.” These data were then used to create a target volume on the InSightec ExAblate Neuro system. The target was the amygdala, uncus, anterior 20 mm of hippocampus, and adjacent parahippocampal gyrus. This volume was approximately 5cm3. Thermocouples were placed on critical skull base structures to monitor skull base heating. RESULTS Adequate focusing of the ultrasound energy was possible in the temporal lobe structures. Using clinically relevant ultrasound parameters (power 900 W, duration 10 sec, frequency 650 kHz), ablative temperatures were not achieved (maximum temperature 46.1°C). Increasing sonication duration to 30 sec demonstrated lesional temperatures in the mesial temporal lobe structures of interest (up to 60.5°C). Heating of the skull base of up to 24.7°C occurred with 30-sec sonications. CONCLUSIONS MRgFUS thermal ablation of the mesial temporal lobe structures relevant in temporal lobe epilepsy is feasible in a laboratory model. Longer sonications were required to achieve temperatures that would create permanent lesions in brain tissue. Heating of the skull base occurred with longer sonications. Blocking algorithms would be required to restrict ultrasound beams causing skull base heating. In the future, MRgFUS may present a minimally invasive, non-ionizing treatment of MTLE.

Publisher

Journal of Neurosurgery Publishing Group (JNSPG)

Subject

Genetics,Animal Science and Zoology

Cited by 41 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3