Holographic mixed-reality neuronavigation with a head-mounted device: technical feasibility and clinical application

Author:

Qi Ziyu12,Li Ye3,Xu Xinghua1,Zhang Jiashu1,Li Fangye1,Gan Zhichao12,Xiong Ruochu1,Wang Qun1,Zhang Shiyu1,Chen Xiaolei1

Affiliation:

1. Department of Neurosurgery, Chinese PLA General Hospital; and

2. School of Medicine, Nankai University, Tianjin, China

3. Department of Neurosurgery, Xuanwu Hospital, Capital Medical University, Beijing; and

Abstract

OBJECTIVE The authors aimed to evaluate the technical feasibility of a mixed-reality neuronavigation (MRN) system with a wearable head-mounted device (HMD) and to determine its clinical application and accuracy. METHODS A semiautomatic registration MRN system on HoloLens smart glasses was developed and tested for accuracy and feasibility. Thirty-seven patients with intracranial lesions were prospectively identified. For each patient, multimodal imaging–based holograms of lesions, markers, and surrounding eloquent structures were created and then imported to the MRN HMD. After a point-based registration, the holograms were projected onto the patient's head and observed through the HMD. The contour of the holograms was compared with standard neuronavigation (SN). The projection of the lesion boundaries perceived by the neurosurgeon on the patient's scalp was then marked with MRN and SN. The distance between the two contours generated by MRN and SN was measured so that the accuracy of MRN could be assessed. RESULTS MRN localization was achieved in all patients. The mean additional time required for MRN was 36.3 ± 6.3 minutes, in which the mean registration time was 2.6 ± 0.9 minutes. A trend toward a shorter time required for preparation was observed with the increase of neurosurgeon experience with the MRN system. The overall median deviation was 4.1 mm (IQR 3.0 mm–4.7 mm), and 81.1% of the lesions localized by MRN were found to be highly consistent with SN (deviation < 5.0 mm). There was a significant difference between the supine position and the prone position (3.7 ± 1.1 mm vs 5.4 ± 0.9 mm, p = 0.001). The magnitudes of deviation vectors did not correlate with lesion volume (p = 0.126) or depth (p = 0.128). There was no significant difference in additional operating time between different operators (37.4 ± 4.8 minutes vs 34.6 ± 4.8 minutes, p = 0.237) or in localization deviation (3.7 ± 1.0 mm vs 4.6 ± 1.5 mm, p = 0.070). CONCLUSIONS This study provided a complete set of a clinically applicable workflow on an easy-to-use MRN system using a wearable HMD, and has shown its technical feasibility and accuracy. Further development is required to improve the accuracy and clinical efficacy of this system.

Publisher

Journal of Neurosurgery Publishing Group (JNSPG)

Subject

Neurology (clinical),General Medicine,Surgery

Cited by 36 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3