Evaluation of neurosurgical implant infection rates and associated pathogens: evidence from 1118 postoperative infections

Author:

Chen Ying1,Zhang Linyan1,Qin Tingting2,Wang Zhenzhen1,Li Ying1,Gu Bing12

Affiliation:

1. Department of Microbiology and Immunology, School of Medical Technology, Xuzhou Medical University; and

2. Clinical Microbiology Laboratory, Affiliated Hospital of Xuzhou Medical University, Xuzhou, China

Abstract

OBJECTIVEVarious implanted materials are used in neurosurgery; however, there remains a lack of pooled data on infection rates (IRs) and infective bacteria over past decades. The goal of this study was to investigate implant infections in neurosurgical procedures in a longitudinal retrospective study and to evaluate the IRs of neurosurgically implanted materials and the distribution of pathogenic microorganisms.METHODSA systematic literature search was conducted using PubMed and Web of Science databases for the time period between 1968 and 2018. Neurosurgical implant infections were studied in 5 subgroups, including operations or diseases, implanted materials, bacteria, distribution by country, and time periods, which were obtained from the literature and statistically analyzed. In this meta-analysis, statistical heterogeneity across studies was tested by using p values and I2 values between studies of associated pathogens. Egger’s test was used for assessing symmetries of funnel plots with Stata 11.0 software. Methodological quality was assessed to judge the risk of bias according to the Cochrane Handbook.RESULTSA total of 22,971 patients from 227 articles satisfied the study’s eligibility criteria. Of these, 1118 cases of infection were reported, and the overall IR was 4.87%. In this study, the neurosurgical procedures or disorders with the top 3 IRs included craniotomy (IR 6.58%), cranioplasty (IR 5.89%), and motor movement disorders (IR 5.43%). Among 13 implanted materials, the implants with the top 3 IRs included polypropylene-polyester, titanium, and polyetheretherketone (PEEK), which were 8.11%, 8.15%, and 7.31%, respectively. Furthermore, the main causative pathogen was Staphylococcus aureus and the countries with the top 3 IRs were Denmark (IR 11.90%), Korea (IR 10.98%), and Mexico (IR 9.26%). Except for the low IR from 1998 to 2007, the overall implant IR after neurosurgical procedures was on the rise.CONCLUSIONSIn this study, the main pathogen in neurosurgery was S. aureus, which can provide a certain reference for the clinic. In addition, the IRs of polypropylene-polyester, titanium, and PEEK were higher than other materials, which means that more attention should be paid to them. In short, the total IR was high in neurosurgical implants and should be taken seriously.

Publisher

Journal of Neurosurgery Publishing Group (JNSPG)

Subject

Neurology (clinical),General Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3