In vitro comparison of the pullout strength of 3 anterior double-screw fixation techniques with different screw angulations

Author:

Fuerderer Sebastian1,Vonhoegen Jan2,Coenen Oliver3,Michael Joern2,Koebke Juergen4,Eysel Peer2

Affiliation:

1. Department for Orthopaedic and Spine Surgery, Klinikum Mutterhaus der Borromäerinnen, Trier;

2. Orthopaedic Department, Cologne University Hospitals, Cologne;

3. Praxis für Orthopädie, Cologne; and

4. Institut für Anatomie II, Cologne University, Cologne, Germany

Abstract

Object The pullout resistance of double-screw fixation systems in anterior spine surgery has been shown to be dependent on screw length as well as on screw angulation. The objective of the study was to evaluate the pullout strength of anterior double-screw systems with different angulations. Methods The authors conducted a comparative pullout test of converging, parallel, and diverging angulations of double-screw systems in human cadavers. Twenty-four human vertebral bodies from T-11 to L-1 were harvested from 8 donors, dissected from surrounding tissue, and matched to 3 different fixation groups. Three systems were tested: VentroFix, with near parallel screw direction; the Hopf Anterior Fixation System (HAFS), with converging screw angulation; and the ART anterior system, with diverging screw angulation. Results The mean (± SD) pullout strength of the VentroFix system was 699 ± 214 N, whereas the HAFS resisted to 591 ± 372 N. The ART anterior system with diverging screws demonstrated a pullout resistance of 810 ± 273 N. There was no significant difference amongst the pullout forces of the 3 groups (p > 0.05). In the HAFS and the ART anterior group, a weak correlation of pullout strength and bone mineral density measured by quantitative CT was found (r = 0.59 and r = 0.62, respectively), whereas the pullout force of the VentroFix system was not correlated with bone mineral density (r = 0.33). Conclusions The in vitro pullout resistance of anterior double-screw systems does not appear to depend on screw angulation.

Publisher

Journal of Neurosurgery Publishing Group (JNSPG)

Subject

General Medicine

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3