A novel, reproducible, and objective method for volumetric magnetic resonance imaging assessment of enhancing glioblastoma

Author:

Kanaly Charles W.1,Mehta Ankit I.1,Ding Dale2,Hoang Jenny K.3,Kranz Peter G.3,Herndon James E.4,Coan April4,Crocker Ian5,Waller Anthony F.5,Friedman Allan H.1,Reardon David A.6,Sampson John H.17

Affiliation:

1. Division of Neurosurgery, Department of Surgery,

2. Department of Neurosurgery, University of Virginia, Charlottesville, Virginia;

3. Department of Radiology,

4. Department of Biostatistics and Bioinformatics, and

5. Department of Radiation Oncology, Emory University, Atlanta, Georgia; and

6. Dana-Farber Cancer Institute, Boston, Massachusetts

7. Department of Pathology, Duke University Medical Center, Durham, North Carolina;

Abstract

Object Robust methodology that allows objective, automated, and observer-independent measurements of brain tumor volume, especially after resection, is lacking. Thus, determination of tumor response and progression in neurooncology is unreliable. The objective of this study was to determine if a semi-automated volumetric method for quantifying enhancing tissue would perform with high reproducibility and low interobserver variability. Methods Fifty-seven MR images from 13 patients with glioblastoma were assessed using our method, by 2 neuroradiologists, 1 neurosurgeon, 1 neurosurgical resident, 1 nurse practitioner, and 1 medical student. The 2 neuroradiologists also performed traditional 1-dimensional (1D) and 2-dimensional (2D) measurements. Intraclass correlation coefficients (ICCs) assessed interobserver variability between measurements. Radiological response was determined using Response Evaluation Criteria In Solid Tumors (RECIST) guidelines and Macdonald criteria. Kappa statistics described interobserver variability of volumetric radiological response determinations. Results There was strong agreement for 1D (RECIST) and 2D (Macdonald) measurements between neuroradiologists (ICC = 0.42 and 0.61, respectively), but the agreement using the authors' novel automated approach was significantly stronger (ICC = 0.97). The volumetric method had the strongest agreement with regard to radiological response (κ = 0.96) when compared with 2D (κ = 0.54) or 1D (κ = 0.46) methods. Despite diverse levels of experience of the users of the volumetric method, measurements using the volumetric program remained remarkably consistent in all users (0.94). Conclusions Interobserver variability using this new semi-automated method is less than the variability with traditional methods of tumor measurement. This new method is objective, quick, and highly reproducible among operators with varying levels of expertise. This approach should be further evaluated as a potential standard for response assessment based on contrast enhancement in brain tumors.

Publisher

Journal of Neurosurgery Publishing Group (JNSPG)

Subject

Genetics,Animal Science and Zoology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3