Abstract
✓ Two cases are presented in which the patients developed an unusual complication following the use of an artificial dural substitute, silicone-coated Dacron (Dura Film). Both patients had undergone removal of a tumor and involved dura. The first patient developed a very thick connective-tissue capsule of the graft material which simulated a recurrent tumor. The second patient developed an acute hemorrhage initially thought to be an acute subdural hematoma beneath the artificial dura 9 weeks after tumor removal and implantation of the graft. A review of the literature and proposed mechanisms of these complications are presented.
Publisher
Journal of Neurosurgery Publishing Group (JNSPG)
Cited by
44 articles.
订阅此论文施引文献