Surgical instruments and catheter damage during ventriculoperitoneal shunt assembly

Author:

Fisher Wilson A. M.1,Catalino Michael P.1,Woolard E. Alice1,Andrews Bethany J.1,Elton Scott1,Quinsey Carolyn1

Affiliation:

1. Department of Neurosurgery, University of North Carolina School of Medicine, Chapel Hill, North Carolina

Abstract

OBJECTIVE Current surgical techniques use common surgical instruments for sterile shunt assembly. This study investigated the impact of using these techniques and surgical instruments on the mechanical integrity of the ventriculoperitoneal shunt system, specifically shunt catheters. METHODS The authors conducted failure testing on 85 rifampin-coated catheters and 85 barium-impregnated catheters using 5 different surgical instruments and 2 different surgical techniques. In technique A, the distal end of the catheter was pushed onto the shunt valve inlet connector with the surgical instrument. In technique B, the catheter was pulled over the inlet connector. One hundred sixty catheters underwent 10-repetition-maximum testing, in which the catheter either failed before completion of 10 consecutive assembly/disassembly repetitions or the catheter completed 10 consecutive repetitions. The authors also conducted 100-repetition-maximum tests on 5 barium-impregnated and 5 rifampin-coated catheters using technique A. RESULTS Catheter failure rates were significantly different among the different instruments used in assembly (p ≤ 0.001). Post hoc analysis showed that using mosquito forceps with shods resulted in a significantly lower catheter failure rate than the other instruments (p < 0.0005). The catheter failure rate of technique A was significantly lower than that of technique B (5% vs 81%, p < 0.001). There was no statistical difference between the failure rates of the barium and rifampin catheters (42% vs 44%, p = 0.9), but the barium catheters outperformed the rifampin catheters in the 100-repetition-maximum trials (p = 0.02). Instrument type (p = 0.0232) and catheter type (p = 0.0096) were both significant factors in determining the number of assembly/disassembly repetitions needed to cause catheter failure. It took an average of 2.79 repetitions of assembly/disassembly to cause catheter failure. DeBakey forceps had significantly lower mean repetitions to failure (mean 1.38) than the Gerald forceps without teeth (mean 2.73, p = 0.05) and bayonet (mean 3.25, p = 0.02). CONCLUSIONS This study was the first of its kind to analyze how physical manipulation affects the mechanical integrity of ventriculoperitoneal shunt components. The authors demonstrated a significantly lower shunt catheter failure rate when mosquito forceps with shods and technique A were used in assembly. Moreover, the authors established that use of DeBakey forceps resulted in failure with fewer assembly/disassembly repetitions than use of the Gerald and bayonet forceps, suggesting that DeBakey forceps are the most damaging instrument.

Publisher

Journal of Neurosurgery Publishing Group (JNSPG)

Subject

Genetics,Animal Science and Zoology

Reference16 articles.

1. Long-term follow-up data from the Shunt Design Trial;Kestle J,2000

2. Ventriculoperitoneal shunt complications in children: an evidence-based approach to emergency department management;Bober J,2016

3. Long-term outcomes of ventriculoperitoneal shunt surgery in patients with hydrocephalus;Reddy GK,2014

4. Ventriculoperitoneal shunt complications: a review;Paff M,2018

5. Epidemiology of cerebrospinal fluid shunting;Bondurant CP,1995

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3