Intraoperative test stimulation versus stereotactic accuracy as a surgical end point: a comparison of essential tremor outcomes after ventral intermediate nucleus deep brain stimulation

Author:

Chen Tsinsue1,Mirzadeh Zaman1,Chapple Kristina M.1,Lambert Margaret1,Evidente Virgilio G. H.2,Moguel-Cobos Guillermo3,Oravivattanakul Srivadee3,Mahant Padma3,Ponce Francisco A.1

Affiliation:

1. Departments of Neurosurgery and

2. Department of Neurology, Movement Disorders Center of Arizona, Scottsdale, Arizona

3. Neurology, Barrow Neurological Institute, St. Joseph’s Hospital and Medical Center, Phoenix; and

Abstract

OBJECTIVEVentral intermediate nucleus deep brain stimulation (DBS) for essential tremor is traditionally performed with intraoperative test stimulation and conscious sedation, without general anesthesia (GA). Recently, the authors reported retrospective data on 17 patients undergoing DBS after induction of GA with standardized anatomical coordinates on T1-weighted MRI sequences used for indirect targeting. Here, they compare prospectively collected data from essential tremor patients undergoing DBS both with GA and without GA (non-GA).METHODSClinical outcomes were prospectively collected at baseline and 3-month follow-up for patients undergoing DBS surgery performed by a single surgeon. Stereotactic, euclidean, and radial errors of lead placement were calculated. Functional (activities of daily living), quality of life (Quality of Life in Essential Tremor [QUEST] questionnaire), and tremor severity outcomes were compared between groups.RESULTSFifty-six patients underwent surgery: 16 without GA (24 electrodes) and 40 with GA (66 electrodes). The mean baseline functional scores and QUEST summary indices were not different between groups (p = 0.91 and p = 0.59, respectively). Non-GA and GA groups did not differ significantly regarding mean postoperative percentages of functional improvement (non-GA, 47.9% vs GA, 48.1%; p = 0.96) or QUEST summary indices (non-GA, 79.9% vs GA, 74.8%; p = 0.50). Accuracy was comparable between groups (mean radial error 0.9 ± 0.3 mm for non-GA and 0.9 ± 0.4 mm for GA patients) (p = 0.75). The mean euclidean error was also similar between groups (non-GA, 1.1 ± 0.6 mm vs GA, 1.2 ± 0.5 mm; p = 0.92). No patient had an intraoperative complication, and the number of postoperative complications was not different between groups (non-GA, n = 1 vs GA, n = 10; p = 0.16).CONCLUSIONSDBS performed with the patient under GA to treat essential tremor is as safe and effective as traditional DBS surgery with intraoperative test stimulation while the patient is under conscious sedation without GA.

Publisher

Journal of Neurosurgery Publishing Group (JNSPG)

Subject

Genetics,Animal Science and Zoology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3