Assessment of motion error for frame-based and noninvasive mask-based fixation using the Leksell Gamma Knife Icon radiosurgery system

Author:

Carminucci Arthur1,Nie Ke2,Weiner Joseph2,Hargreaves Eric1,Danish Shabbar F.1

Affiliation:

1. Department of Neurological Surgery, Rutgers University; and

2. Department of Radiation Oncology, Rutgers Cancer Institute of New Jersey, Rutgers Robert Wood Johnson Medical School, New Brunswick, New Jersey

Abstract

OBJECTIVEThe Leksell Gamma Knife Icon (GK Icon) radiosurgery system can utilize cone-beam computed tomography (CBCT) to evaluate motion error. This study compares the accuracy of frame-based and frameless mask-based fixation using the Icon system.METHODSA retrospective cohort study was conducted to evaluate patients who had undergone radiosurgery with the GK Icon system between June and December 2017. Patients were immobilized in either a stereotactic head frame or a noninvasive thermoplastic mask with stereotactic infrared (IR) camera monitoring. Setup error was defined as displacement of the skull in the stereotactic space upon setup as noted on pretreatment CBCT compared to its position in the stereotactic space defined by planning MRI for frame patients and defined as skull displacement on planning CBCT compared to its position on pretreatment CBCT for mask patients. For frame patients, the intrafractionation motion was measured by comparing pretreatment and posttreatment CBCT. For mask patients, the intrafractionation motion was evaluated by comparing pretreatment CBCT and additional CBCT obtained during the treatment. The translational and rotational errors were recorded.RESULTSData were collected from 77 patients undergoing SRS with the GK Icon. Sixty-four patients underwent frame fixation, with pre- and posttreatment CBCT studies obtained. Thirteen patients were treated using mask fixation to deliver a total of 33 treatment fractions. Mean setup and intrafraction translational and rotation errors were small for both fixation systems, within 1 mm and 1° in all axes. Yet mask fixation demonstrated significantly larger intrafraction errors than frame fixation. Also, there was greater variability in both setup and intrafraction errors for mask fixation than for frame fixation in all translational and rotational directions. Whether the GK treatment was for metastasis or nonmetastasis did not influence motion uncertainties between the two fixation types. Additionally, monitoring IR-based intrafraction motion for mask fixation—i.e., the number of treatment stoppages due to reaching the IR displacement threshold—correlated with increasing treatment time.CONCLUSIONSCompared to frame-based fixation, mask-based fixation demonstrated larger motion variations. The variability in motion error associated with mask fixation must be taken into account when planning for small lesions or lesions near critical structures.

Publisher

Journal of Neurosurgery Publishing Group (JNSPG)

Subject

Genetics,Animal Science and Zoology

Reference40 articles.

1. Whole-procedure clinical accuracy of gamma knife treatments of large lesions;Ma;Med Phys,2008

2. The use of cone beam computed tomography for image guided Gamma Knife stereotactic radiosurgery: initial clinical evaluation;Li;Int J Radiat Oncol Biol Phys,2016

3. The TALON removable head frame system for stereotactic radiosurgery/radiotherapy: measurement of the repositioning accuracy;Salter;Int J Radiat Oncol Biol Phys,2001

4. Preliminary evaluation of a novel thermoplastic mask system with intra-fraction motion monitoring for future use with image-guided Gamma Knife;Li;Cureus,2016

5. The stereotaxic method and radiosurgery of the brain;Leksell;Acta Chir Scand,1951

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3