Author:
Macon James B.,Poletti Charles E.
Abstract
✓ Intraoperative recordings of conducted bipolar epidural somatosensory evoked potentials (SEP's) generated by unilateral common peroneal nerve stimulation have been obtained in 27 patients. The SEP's were multiphasic, 0.3 to 1.5 µV in amplitude, and recorded in 100% of patients with normal cords or in patients with spinal lesions, at a site caudal to the lesions. Control spinal conduction velocities (CV's), measured in the midthoracic to lower cervical regions, were in the range of 65 to 85 m/sec. Control lumbar and lower thoracic CV's were in the range of 30 to 45 m/sec. The CV values were obtained periodically throughout the course of surgery and were plotted as a function of time. In control patients with extradural lesions and neuroleptic anesthesia, the CV's remained constant (± 3%). The consistency, sensitivity, and safety of SEP recordings obtained by this technique make precise monitoring readily available during spinal operations.
Publisher
Journal of Neurosurgery Publishing Group (JNSPG)
Cited by
54 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献