Semiautomated intraoperative measurement of Cobb angle and coronal C7 plumb line using deep learning and computer vision for scoliosis correction: a feasibility study

Author:

Gami Parth1,Qiu Kelly1,Kannappan Sindhu1,Alperin Yoel1,Biase Gaetano De2,Buchanan Ian A.2,Quiñones-Hinojosa Alfredo2,Abode-Iyamah Kingsley2

Affiliation:

1. Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology, Atlanta, Georgia; and

2. Department of Neurosurgery, Mayo Clinic, Jacksonville, Florida

Abstract

OBJECTIVE Scoliosis is a degenerative disease with a 3D deformity in the alignment of the spinal column. Surgical spinal correction outcomes are heavily dependent on the surgeon’s expertise and use of visual cues because of time requirements, lack of automation, and radiation exposure associated with current intraoperative measurement techniques. In this study, the authors sought to validate a novel, nonradiographic, and semiautomated device that measures spinal alignment intraoperatively using deep learning and computer vision. METHODS To obtain spinal alignment metrics intraoperatively, the surgeon placed 3D-printed markers made of acrylonitrile butadiene styrene (ABS) plastic at designated locations in the surgical field. With the high-definition camera of the device, the surgeon can take an image of the markers in the surgical field. Images are processed through a computer vision model that detects the location of the markers and calculates the Cobb angle and coronal plumb line. The marker detection model was trained on 100 images and tested on 130 images of the ABS markers in various conditions. To verify the Cobb angle calculation, 50 models of angle templates from 0° to 180° in 3.6735° increments were created for testing. To verify the plumb line calculation, 21 models of plumb line measurements from −10 to +10 cm in increments of 1 cm were created for testing. A validation study was performed on a scoliotic cadaver model, and the radiographic calculations for Cobb angle and plumb line were compared with the device’s calculations. RESULTS The area under the curve for the marker detection model was 0.979 for Cobb angle white, 0.791 for Cobb angle black, and 1 for the plumb line model. The average absolute difference between expected and measured Cobb angles on the verification models was 1.726° ± 1.259°, within the clinical acceptable error of 5°. The average absolute difference between the expected and measured plumb lines on the verification models was 0.415 ± 0.255 cm. For the cadaver validation study, the differences between the radiographic and device calculations for the Cobb angle and plumb line were 2.78° and 0.29 cm, respectively. CONCLUSIONS The authors developed and validated a nonradiographic, semiautomated device that utilizes deep learning and computer vision to measure spinal metrics intraoperatively.

Publisher

Journal of Neurosurgery Publishing Group (JNSPG)

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3