Abstract

The potential of near infrared (NIR) spectroscopy for the determination of the chemical composition of poultry excreta was investigated, within the framework of studies on heritability of digestive efficiency in broilers. Samples in the calibration and validation databases (DB1 and DB2) corresponded to animals fed with a similar wheat-based diet. A second validation study was performed on excreta samples from animals fed more variable diets, including peas and maize (DB3). Excreta samples were freeze-dried and ground. Near infrared reflectance spectra were taken on a monochromator spectrometer between 400nm and 2500nm. Samples were analysed for mineral matter (MM), gross energy (GE), starch, crude fat (CFAT), total nitrogen (NTOT), uric acid nitrogen (NUA) and protein nitrogen estimated directly (PNTERP) or by difference between NTOT and NUA (PNUA). Depending on the parameters studied, 250 to 700 samples were analysed by reference methods. The standard error of cross-validation ( SECV) and R2 of calibrations were: 0.60% and 0.96 for MM, 166 kJ kg−1 and 0.99 for GE, 0.59% and 1.00 for starch, 0.44% and 0.99 for CFAT, 0.25% and 0.89 for NTOT and 0.22% and 0.97 for NUA, respectively. Calibration for PNTERP ( SECV=0.07%; R2=0.98) was much more precise than PNUA ( SECV=0.21%, R2=0.85). Validation carried out on databases DB2 and DB3 resulted in standard errors of prediction (on DB2) and extrapolation (on DB3) generally higher than SECV, while remaining relatively precise with prediction r2 values from 0.83 to 0.99 and extrapolation r2 from 0.86 to 0.98, with the exception of PNUA for which r2 was 0.22 and 0.64, respectively. For some parameters, the lower validation performance was due to biases, particularly in the case CFAT and NUA for prediction and MM, GE and NUA for extrapolation. Global calibrations made with DB1+DB2+DB3 were more precise (GE, NTOT) or equally precise (all other parameters) than with DB1 alone. These results confirmed the potential precision of calibrations for the major organic compounds in poultry excreta and suggested that their use could be extended to excreta issued from a wider range of diets without losing precision.

Publisher

SAGE Publications

Subject

Spectroscopy

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3