Determination of Total Carbon and Nitrogen Content in a Range of Tropical Soils Using near Infrared Spectroscopy: Influence of Replication and Sample Grinding and Drying

Author:

Barthès Bernard G.1,Brunet Didier1,Ferrer Henri1,Chotte Jean-Luc1,Feller Christian2

Affiliation:

1. UR SeqBio (Séquestration du carbone et bio-fonctionnement des sols), IRD (Institut de recherche pour le développement), BP 64501, 34394 Montpellier cedex 5, France

2. UR SeqBio (Séquestration du carbone et bio-fonctionnement des sols), IRD (Institut de recherche pour le développement), BP 434, 101 Antananarivo, Madagascar

Abstract

Near infrared (NIR) reflectance spectroscopy has been receiving increased attention for the rapid and inexpensive determination of soil properties and of total carbon (Ct) and nitrogen content (Nt) in particular. However, methodological aspects such as sample grinding and drying or replication have not been addressed extensively. The objectives of the paper were, thus, to assess how NIR predictions of Ct and Nt were affected by sample grinding (2 mm sieving vs. 0.2 mm grinding), drying (air-drying vs oven-drying at 40°C during 24 h) and replication (use of one to six sub-samples to determine average spectra). This was performed on a range of tropical soils that differed widely in mineralogy (low and high activity clay soils, allophanic soils) and texture (sandy to clayey). The accuracy of the NIR predictions of Ct and Nt was higher with oven-dried compared to air-dried samples and, more markedly, with 0.2 mm ground compared to 2 mm sieved samples. Replication had a positive effect on NIR predictions when 2 mm sieved samples were used, especially for air-dried samples, but this effect was not clear with 0.2 mm ground samples. Thus, the most accurate predictions of Ct and Nt were obtained with oven-dried finely ground samples, with limited response to sample replication. Accurate predictions were, however, also obtained with four replicates on oven-dried 2 mm sieved samples. Acceptable and less tedious results could, thus, be achieved when replacing fine grinding by replication. Even with this procedure, the r2 between predicted (NIR) and measured (reference) values was 0.9 and the ratio of standard error of prediction to mean ( CV%) was 20% which can be considered satisfactory for the heterogeneous sample set under study.

Publisher

SAGE Publications

Subject

Spectroscopy

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3