Determination of Optical Parameters and Moisture Content of Wood with Visible–Near Infrared Spectroscopy

Author:

Haddadi Ataollah1,Hans Guillaume1,Leblon Brigitte1,Pirouz Zarin2,Tsuchikawa Satoru3,Nader Joseph4,Groves Kevin2

Affiliation:

1. Faculty of Forestry and Environmental Management, University of New Brunswick, 28 Dineen Drive, Fredericton, NB, Canada E3B 5A3

2. FPInnovations - Wood Products, 2665 East Mall, Vancouver, BC, Canada V6T 1W5

3. Graduate School of Bioagricultural Sciences, Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8601, Japan

4. FPInnovations - Forest Operations, 570 Boulevard Saint-Jean, Pointe-Claire, QC, Canada H9R 3J9

Abstract

We used the Kubelka-Munk theory equations for calculating the absorption coefficient (Kλ), the scattering coefficient ( Sλ), the transport absorption (σλa), the reduced scattering coefficient [σλs(1 – g)] and the penetration depth (δλ) from visible-near infrared reflectance spectra acquired over thin samples of quaking aspen and black spruce conditioned at three different moisture levels. The computed absorption and scattering coefficients varied from 0.1 mm−1 to 4.0 mm−1 and from 5.5 mm−1 to 10.0 mm−1, respectively. The absorption coefficients varied according to the absorption band, but the scattering coefficients decreased slowly towards high wavelengths. The sample moisture content was then estimated using the partial least squares (PLS) regression method from the Kλ and/or Sλ spectra, and the resulting PLS models were compared to those obtained with raw and transformed [multiplicative scatter corrected (MSC), first and second derivative] absorption spectra. The best PLS models for black spruce, quaking aspen and both species were obtained when only the 800–1800 nm range was used with the raw or MSC spectra. They led to a root mean square error of cross validation ( RMSECV) of 1.40%, 1.09% and 1.23%, respectively, and to a coefficient of determination ( R2CV) higher than 0.94. We also found that the Kλ spectra between 800 nm and 1800 nm can provide PLS models having an acceptable accuracy for moisture content estimation ( R2CV = 0.83 and RMSECV = 2.32%), regardless of the species.

Publisher

SAGE Publications

Subject

Spectroscopy

Reference76 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3