Rapid and Sensitive Determination of Diacetylpolyamines in Human Fingernail by Ultraperformance Liquid Chromatography Coupled with Electrospray Ionization Tandem Mass Spectrometry

Author:

Min Jun Zhe12,Morota Yuka1,Jiang Ying-Zi2,Li Gao2,Jin Dongri2,Kang Dongzhou2,Yu Hai-Fu3,Inoue Koichi1,Todoroki Kenichiro1,Toyo'oka Toshimasa1

Affiliation:

1. Laboratory of Analytical and Bio-Analytical Chemistry, School of Pharmaceutical Sciences, University of Shizuoka, 52-1 Yada, Suruga-ku, Shizuoka 422-8526, Japan

2. Key Laboratory for Natural Resource of Changbai Mountain & Functional Molecules, Ministry of Education, College of Pharmacy, Yanbian University, Yanji 133002, Jilin Province, China

3. Fengxian Branch of Shanghai Sixth People's Hospital, Shanghai 201400, China

Abstract

A rapid and sensitive ultraperformance liquid chromatography coupled with electrospray ionization tandem mass spectrometry (UPLC-ESI-MS/MS) method has been developed and validated for quantitatively determining diacetylpolyamines in the human fingernail. N1, N8-diacetylspermidine (DiAct-Spd), N1, N12-diacetylspermine (DiAct-Spm) and 1,6-diaminohexane (DAH) [the internal standard (IS)] were extracted from human fingernail samples by a MeOH:5 M HCl solution, followed by 4-( N,N-dimethylaminosulfonyl)-7-fluoro-2,1,3-benzoxadiazole (DBD-F) derivatization, and then separated on an ACQUITY BEH C18 column with a gradient elution of acetonitrile and water containing 0.1% formic acid. The derivatives of the diacetylpolyamines were fully separated within a short run time (3.0 min). The triple quadrupole mass spectrometric detection was performed in the multiple reactions monitoring (MRM) mode by the UPLC-ESI-MS/MS system in the positive ionization mode. MRM using the fragmentation transitions of m/z 455.20 → 100.07, 737.25 → 100.07 and 567.10 → 479.07 in the positive ESI mode was performed to quantify DiAct-Spd, DiAct-Spm and IS, respectively. The calibration curve is between 0.04 ng mL−1 and 10 ng mL−1 for DiAct-Spd and DiAct-Spm. The detection limits (signal to noise ratio of five) were 5–10 pg mL−1. A good linearity was achieved from the calibration curves ( r2 > 0.9999), and the intra-day and inter-day assay precisions were less than 7.06%. Furthermore, the recoveries (%) of the diacetylpolyamines spiked in the human fingernails were 79.18–97.11. The present method proved that the high sensitivity is characterized by the specificity and feasibility of the sample analysis. Consequently, the proposed method was used to analyze human fingernail samples from 15 lung-cancer patients and 22 healthy volunteers. Diacetylpolyamines were detected from the fingernails of the lung-cancer patients for the first time. The concentration of DiAct-Spd in the lung-cancer patient group tended to be higher than those in the healthy volunteers.

Publisher

SAGE Publications

Subject

Spectroscopy,Atomic and Molecular Physics, and Optics,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3