Probe electrospray ionization (PESI) using a 0.2 mm outside diameter titanium wire was performed and the generated ions were introduced into the mass spectrometer via a discontinuous atmospheric pressure interface using a pinch valve. Time-lapse PESI mass spectra were acquired by gradually increasing delay time for the pinch valve opening with respect to the start of each electrospray event when a high voltage was applied. The opening time of the pinch valve was 20 ms. Time-resolved PESI mass spectra showed marked differences for 10 mM NaCl, 10−5 M gramicidin S and insulin in H2O/CH3OH/CH3COOH (65/35/1) with and without the addition of 10 mM CH3COONH4. This was ascribed to the pH change of the liquid attached to the needle caused by electrochemical reactions taking place at the interface between the metal probe and the solution. NaCl cluster ions appeared only after the depletion of analytes. For the mixed solution of 10−5 M cytochrome c, insulin, and gramicidin S in H2O/CH3OH/CH3COOH (65/35/1), a sequential appearance of analyte ions in the order of cytochrome c → insulin → gramicidin S was observed. The present technique was applied to three narcotic samples, methamphetamine, morphine, and codeine. Limits of detection for these compounds were 10 ppb in H2O/CH3OH (1/1) for the single sampling with a pinch valve opening time of 200 ms.

Publisher

SAGE Publications

Subject

Spectroscopy,Atomic and Molecular Physics, and Optics,General Medicine

Cited by 20 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3