Three-Year Outcomes of Biodegradable Polymer-Coated Ultra-Thin (60 µm) Sirolimus-Eluting Stents in Real-World Clinical Practice

Author:

Chandwani Prakash1,Meel Bhavesh1,Singhal Rahul1,Jangid Kushal1,Ahmed Rasheed2,Yadav Mukesh3,Gupta Anshul Kumar1,Chopra Rohit2

Affiliation:

1. Heart and General Hospital, Rajasthan, India

2. Shalby Hospital, Rajasthan, India

3. Kedia Hospital, Rajasthan, India

Abstract

Introduction: Although drug-eluting stents (DES) have outclassed the use of bare metal stents, the safety and efficacy of DES at long-term follow-up has still been conflicting because of increased occurrence of late or very late restenosis and stent thrombosis after DES implantation. Hence, the present study was aimed to evaluate the 3-year safety and clinical performance of biodegradable polymer-coated ultra-thin (60 μm) sirolimus-eluting stent (SES) in real-world patients with coronary artery disease (CAD). Materials and Methods: This was a physician-initiated, retrospective, single-centre, observational study that included 237 consecutive patients who had previously undergone implantation of only Supraflex SES (Sahajanand Medical Technologies Pvt Ltd, Surat, India) for the treatment of CAD. Follow-up was received after 1 year and 3 years of stent implantation. The primary endpoint was major adverse cardiac events (MACE), a composite of cardiac death, myocardial infarction (MI) and target lesion revascularisation (TLR). Stent thrombosis was considered as a safety endpoint. Results: The mean age of patients was 64.1 ± 10.2 years, and 192 (81.0%) patients were male. The average stent length and diameter were 24.4 ± 9.0 mm and 3.1 ± 0.4 mm, respectively. The cumulative MACE rate at 3 years follow-up was 6.5% which included 4 (1.8%) cardiac deaths, 6 (2.8%) MI, and 4 (1.8%) TLR. There were 2 (0.9%) cases of stent thrombosis. Conclusion: Treatment of patients with CAD in real-world clinical practice was associated with sustained clinical safety and low rates of restenosis, stent thrombosis and MACE up to 3 years after Supraflex SES implantation. Key words: Coronary artery disease, Percutaneous coronary intervention

Publisher

Academy of Medicine, Singapore

Subject

General Medicine

Reference43 articles.

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3