Affiliation:
1. Heart and General Hospital, Rajasthan, India
2. Shalby Hospital, Rajasthan, India
3. Kedia Hospital, Rajasthan, India
Abstract
Introduction: Although drug-eluting stents (DES) have outclassed the use of bare metal stents, the safety and efficacy of DES at long-term follow-up has still been conflicting because of increased occurrence of late or very late restenosis and stent thrombosis after DES implantation. Hence, the present study was aimed to evaluate the 3-year safety and clinical performance of biodegradable polymer-coated ultra-thin (60 μm) sirolimus-eluting stent (SES) in real-world patients with coronary artery disease (CAD). Materials and Methods: This was a physician-initiated, retrospective, single-centre, observational study that included 237 consecutive patients who had previously undergone implantation of only Supraflex SES (Sahajanand Medical Technologies Pvt Ltd, Surat, India) for the treatment of CAD. Follow-up was received after 1 year and 3 years of stent implantation. The primary endpoint was major adverse cardiac events (MACE), a composite of cardiac death, myocardial infarction (MI) and target lesion revascularisation (TLR). Stent thrombosis was considered as a safety endpoint. Results: The mean age of patients was 64.1 ± 10.2 years, and 192 (81.0%) patients were male. The average stent length and diameter were 24.4 ± 9.0 mm and 3.1 ± 0.4 mm, respectively. The cumulative MACE rate at 3 years follow-up was 6.5% which included 4 (1.8%) cardiac deaths, 6 (2.8%) MI, and 4 (1.8%) TLR. There were 2 (0.9%) cases of stent thrombosis. Conclusion: Treatment of patients with CAD in real-world clinical practice was associated with sustained clinical safety and low rates of restenosis, stent thrombosis and MACE up to 3 years after Supraflex SES implantation. Key words: Coronary artery disease, Percutaneous coronary intervention
Publisher
Academy of Medicine, Singapore
Reference43 articles.
1. World Health Organization. The Global Cardiovascular Disease (CVD) Crisis 2017. Available at: https://www.who.int/cardiovascular_diseases/en/. Accessed on 28 January 2019.
2. Simard T, Hibbert B, Ramirez FD, Froeschl M, Chen YX, O'Brien ER. The evolution of coronary stents: a brief review. Can J Cardiol 2014;30:35-45.
3. Ho MY, Chen CC, Wang CY, Chang SH, Hsieh MJ, Lee CH, et al. The development of coronary artery stents: from bare-metal to bio-resorbable types. Metals 2016;6:168.
4. Foerst J, Vorpahl M, Engelhardt M, Koehler T, Tiroch K, Wessely R. Evolution of coronary stents: from bare-metal stents to fully biodegradable, drug-eluting stents. Combination Products in Therapy 2013;3:9-24.
5. Lim V, Chan C. Prevention of restenosis after percutaneous coronary intervention: the continuing challenge. Ann Acad Med Singapore 2002;31:102-6.
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献