Effectiveness of the BreatheSuite Device in Assessing the Technique of Metered-Dose Inhalers: Validation Study

Author:

Alwashmi Meshari FORCID,Mugford GeraldORCID,Vokey BrettORCID,Abu-Ashour WaseemORCID,Hawboldt JohnORCID

Abstract

Background The majority of medications used in treating asthma and chronic obstructive pulmonary disease (COPD) are taken through metered-dose inhalers (MDIs). Studies have reported that most patients demonstrate poor inhaler technique, which has resulted in poor disease control. Digital Health applications have the potential to improve the technique and adherence of inhaled medications. Objective This study aimed to validate the effectiveness of the BreatheSuite MDI device in assessing the technique of taking a dose via an MDI. Methods The study was a validation study. Thirty participants who self-reported a diagnosis of asthma or COPD were recruited from community pharmacies in Newfoundland and Labrador, Canada. Participants used a BreatheSuite MDI device attached to a placebo MDI and resembled taking 3 doses. Pharmacists used a scoring sheet to evaluate the technique of using the MDI. An independent researcher compared the results of the pharmacist’s scoring sheet with the results of the BreatheSuite device. Results This study found that the BreatheSuite MDI can objectively detect several errors in the MDI technique. The data recorded by the BreatheSuite MDI device showed that all participants performed at least one error in using the MDI. The BreatheSuite device captured approximately 40% (143/360) more errors compared to observation alone. The distribution of participants who performed errors in MDI steps as recorded by BreatheSuite compared to errors reported by observation alone were as follows: shaking before actuation, 33.3% (30/90) versus 25.5% (23/90); upright orientation of the inhaler during actuation, 66.7% (60/90) versus 18.87% (17/90); coordination (actuating after the start of inhalation), 76.6% (69/90) versus 35.5% (32/90); and duration of inspiration, 96.7% (87/90) versus 34.4% (31/90). Conclusions The BreatheSuite MDI can objectively detect several errors in the MDI technique, which were missed by observation alone. It has the potential to enhance treatment outcomes among patients with chronic lung diseases.

Publisher

JMIR Publications Inc.

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3