Association of Smartwatch-Based Heart Rate and Physical Activity With Cardiorespiratory Fitness Measures in the Community: Cohort Study (Preprint)

Author:

Zhang YuankaiORCID,Wang XuzhiORCID,Pathiravasan Chathurangi HORCID,Spartano Nicole LORCID,Lin HonghuangORCID,Borrelli BelindaORCID,Benjamin Emelia JORCID,McManus David DORCID,Larson Martin GORCID,Vasan Ramachandran SORCID,Shah Ravi VORCID,Lewis Gregory DORCID,Liu ChunyuORCID,Murabito Joanne MORCID,Nayor MatthewORCID

Abstract

BACKGROUND

Resting heart rate (HR) and routine physical activity are associated with cardiorespiratory fitness levels. Commercial smartwatches permit remote HR monitoring and step count recording in real-world settings over long periods of time, but the relationship between smartwatch-measured HR and daily steps to cardiorespiratory fitness remains incompletely characterized in the community.

OBJECTIVE

This study aimed to examine the association of nonactive HR and daily steps measured by a smartwatch with a multidimensional fitness assessment via cardiopulmonary exercise testing (CPET) among participants in the electronic Framingham Heart Study.

METHODS

Electronic Framingham Heart Study participants were enrolled in a research examination (2016-2019) and provided with a study smartwatch that collected longitudinal HR and physical activity data for up to 3 years. At the same examination, the participants underwent CPET on a cycle ergometer. Multivariable linear models were used to test the association of CPET indices with nonactive HR and daily steps from the smartwatch.

RESULTS

We included 662 participants (mean age 53, SD 9 years; n=391, 59% women, n=599, 91% White; mean nonactive HR 73, SD 6 beats per minute) with a median of 1836 (IQR 889-3559) HR records and a median of 128 (IQR 65-227) watch-wearing days for each individual. In multivariable-adjusted models, lower nonactive HR and higher daily steps were associated with higher peak oxygen uptake (VO<sub>2</sub>), % predicted peak VO<sub>2</sub>, and VO<sub>2</sub> at the ventilatory anaerobic threshold, with false discovery rate (FDR)–adjusted <i>P</i> values &lt;.001 for all. Reductions of 2.4 beats per minute in nonactive HR, or increases of nearly 1000 daily steps, corresponded to a 1.3 mL/kg/min higher peak VO<sub>2</sub>. In addition, ventilatory efficiency (V<sub>E</sub>/VCO<sub>2</sub>; FDR-adjusted <i>P</i>=.009), % predicted maximum HR (FDR-adjusted <i>P</i>&lt;.001), and systolic blood pressure-to-workload slope (FDR-adjusted <i>P</i>=.01) were associated with nonactive HR but not associated with daily steps.

CONCLUSIONS

Our findings suggest that smartwatch-based assessments are associated with a broad array of cardiorespiratory fitness responses in the community, including measures of global fitness (peak VO<sub>2</sub>), ventilatory efficiency, and blood pressure response to exercise. Metrics captured by wearable devices offer a valuable opportunity to use extensive data on health factors and behaviors to provide a window into individual cardiovascular fitness levels.

Publisher

JMIR Publications Inc.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3