Effects of Self-Service Blood Pressure Measurement in Outpatient Obstetrics Clinics on waiting time, satisfaction of pregnant women in a tertiary hospital: Cross-sectional Survey (Preprint)

Author:

Xie WanhuaORCID,Gao Yunhe,Tan Weichi

Abstract

BACKGROUND

In the conventional method, the blood pressure values of pregnant women were measured by nurses in the obstetrics outpatient clinics, and then were entered into the computer system.The pregnant women should wait for long time to complete this process.We hypothesized that the self-service blood pressure measurement by pregnant women could be a better option rather than measuring the blood pressure by nurses.

OBJECTIVE

This study aimed to analyze the effect of self-service blood pressure measurement in obstetrical outpatient clinic on waiting time, satisfaction of pregnant women and outpatient volume, and provide reference for the optimization of outpatient service processes.

METHODS

This was a cross-sectional study. The waiting time and satisfaction degree of pregnant women, as well as the outpatient volume in the Obstetrics Outpatient Clinic were compared on the use of self-service blood pressure measurement system with the conventional method. A total of 519 pregnant women in the obstetrics outpatient clinics of Guangzhou Women and Children’s Medical Center in China participated in the satisfaction survey. The sample means were compared with t-test.

RESULTS

Compared to wait a longer queue for blood pressure measured by nurses, after using the self-service blood pressure measurement system, the waiting time of pregnant women for blood pressure measurement was significantly reduced from (18.57±9.68) min to (2.39±1.96) min (P<0.001). In addition, the satisfaction degree of pregnant women was significantly increased (P<0.001), and the monthly outpatient volume was significantly increased (P=0.02,P<0.05).

CONCLUSIONS

This study showed that after implementation of self-service blood pressure measurement, the waiting time of the pregnant women for blood pressure measurement was decreased significantly, while the satisfactory degree and outpatient flow were increased significantly, improving the cost-effectiveness.Therefore, this method is worth to be popularized in clinical practices. Relevance to clinical practice: How to use medical intelligence in clinical practices, replace manual works by self-service devices to address the high outpatient flow, high work load of medical personnel, and improve the experience of patients in seeking medical services are the most concerned issues by both patients as well as hospital managers.This study demonstrated that the self-service blood pressure measurement as a promising strategy in clinical practices and provided reference for the optimization of outpatient service processes.

CLINICALTRIAL

This study was approved by the Ethics Committee of the Guangzhou Women and Children’s Medical Center (approval number:SFE-KL-46401; Supplementary file 4). All the pregnant women included in this study signed the informed consent form.