Abstract
Background
Inhaled anesthetics in the operating room are potent greenhouse gases and are a key contributor to carbon emissions from health care facilities. Real-time clinical decision support (CDS) systems lower anesthetic gas waste by prompting anesthesia professionals to reduce fresh gas flow (FGF) when a set threshold is exceeded. However, previous CDS systems have relied on proprietary or highly customized anesthesia information management systems, significantly reducing other institutions’ accessibility to the technology and thus limiting overall environmental benefit.
Objective
In 2018, a CDS system that lowers anesthetic gas waste using methods that can be easily adopted by other institutions was developed at the University of California San Francisco (UCSF). This study aims to facilitate wider uptake of our CDS system and further reduce gas waste by describing the implementation of the FGF CDS toolkit at UCSF and the subsequent implementation at other medical campuses within the University of California Health network.
Methods
We developed a noninterruptive active CDS system to alert anesthesia professionals when FGF rates exceeded 0.7 L per minute for common volatile anesthetics. The implementation process at UCSF was documented and assembled into an informational toolkit to aid in the integration of the CDS system at other health care institutions. Before implementation, presentation-based education initiatives were used to disseminate information regarding the safety of low FGF use and its relationship to environmental sustainability. Our FGF CDS toolkit consisted of 4 main components for implementation: sustainability-focused education of anesthesia professionals, hardware integration of the CDS technology, software build of the CDS system, and data reporting of measured outcomes.
Results
The FGF CDS system was successfully deployed at 5 University of California Health network campuses. Four of the institutions are independent from the institution that created the CDS system. The CDS system was deployed at each facility using the FGF CDS toolkit, which describes the main components of the technology and implementation. Each campus made modifications to the CDS tool to best suit their institution, emphasizing the versatility and adoptability of the technology and implementation framework.
Conclusions
It has previously been shown that the FGF CDS system reduces anesthetic gas waste, leading to environmental and fiscal benefits. Here, we demonstrate that the CDS system can be transferred to other medical facilities using our toolkit for implementation, making the technology and associated benefits globally accessible to advance mitigation of health care–related emissions.