Wearable Devices to Diagnose and Monitor the Progression of COVID-19 Through Heart Rate Variability Measurement: Systematic Review and Meta-Analysis

Author:

Sanches Carlos AlbertoORCID,Silva Graziella AlvesORCID,Librantz Andre Felipe HenriquesORCID,Sampaio Luciana Maria MalosaORCID,Belan Peterson AdrianoORCID

Abstract

Background Recent studies have linked low heart rate variability (HRV) with COVID-19, indicating that this parameter can be a marker of the onset of the disease and its severity and a predictor of mortality in infected people. Given the large number of wearable devices that capture physiological signals of the human body easily and noninvasively, several studies have used this equipment to measure the HRV of individuals and related these measures to COVID-19. Objective The objective of this study was to assess the utility of HRV measurements obtained from wearable devices as predictive indicators of COVID-19, as well as the onset and worsening of symptoms in affected individuals. Methods A systematic review was conducted searching the following databases up to the end of January 2023: Embase, PubMed, Web of Science, Scopus, and IEEE Xplore. Studies had to include (1) measures of HRV in patients with COVID-19 and (2) measurements involving the use of wearable devices. We also conducted a meta-analysis of these measures to reduce possible biases and increase the statistical power of the primary research. Results The main finding was the association between low HRV and the onset and worsening of COVID-19 symptoms. In some cases, it was possible to predict the onset of COVID-19 before a positive clinical test. The meta-analysis of studies reported that a reduction in HRV parameters is associated with COVID-19. Individuals with COVID-19 presented a reduction in the SD of the normal-to-normal interbeat intervals and root mean square of the successive differences compared with healthy individuals. The decrease in the SD of the normal-to-normal interbeat intervals was 3.25 ms (95% CI −5.34 to −1.16 ms), and the decrease in the root mean square of the successive differences was 1.24 ms (95% CI −3.71 to 1.23 ms). Conclusions Wearable devices that measure changes in HRV, such as smartwatches, rings, and bracelets, provide information that allows for the identification of COVID-19 during the presymptomatic period as well as its worsening through an indirect and noninvasive self-diagnosis.

Publisher

JMIR Publications Inc.

Subject

Health Informatics

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3