Process Evaluation of a Wireless Wearable Continuous Vital Signs Monitoring Intervention in 2 General Hospital Wards: Mixed Methods Study

Author:

Leenen Jobbe P LORCID,Rasing Henriëtte J MORCID,Kalkman Cor JORCID,Schoonhoven LisetteORCID,Patijn Gijsbert AORCID

Abstract

Background Continuous monitoring of vital signs (CMVS) using wearable wireless sensors is increasingly available to patients in general wards and can improve outcomes and reduce nurse workload. To assess the potential impact of such systems, successful implementation is important. We developed a CMVS intervention and implementation strategy and evaluated its success in 2 general wards. Objective We aimed to assess and compare intervention fidelity in 2 wards (internal medicine and general surgery) of a large teaching hospital. Methods A mixed methods sequential explanatory design was used. After thorough training and preparation, CMVS was implemented—in parallel with the standard intermittent manual measurements—and executed for 6 months in each ward. Heart rate and respiratory rate were measured using a chest-worn wearable sensor, and vital sign trends were visualized on a digital platform. Trends were routinely assessed and reported each nursing shift without automated alarms. The primary outcome was intervention fidelity, defined as the proportion of written reports and related nurse activities in case of deviating trends comparing early (months 1-2), mid- (months 3-4), and late (months 5-6) implementation periods. Explanatory interviews with nurses were conducted. Results The implementation strategy was executed as planned. A total of 358 patients were included, resulting in 45,113 monitored hours during 6142 nurse shifts. In total, 10.3% (37/358) of the sensors were replaced prematurely because of technical failure. Mean intervention fidelity was 70.7% (SD 20.4%) and higher in the surgical ward (73.6%, SD 18.1% vs 64.1%, SD 23.7%; P<.001). Fidelity decreased over the implementation period in the internal medicine ward (76%, 57%, and 48% at early, mid-, and late implementation, respectively; P<.001) but not significantly in the surgical ward (76% at early implementation vs 74% at midimplementation [P=.56] vs 70.7% at late implementation [P=.07]). No nursing activities were needed based on vital sign trends for 68.7% (246/358) of the patients. In 174 reports of 31.3% (112/358) of the patients, observed deviating trends led to 101 additional bedside assessments of patients and 73 consultations by physicians. The main themes that emerged during interviews (n=21) included the relative priority of CMVS in nurse work, the importance of nursing assessment, the relatively limited perceived benefits for patient care, and experienced mediocre usability of the technology. Conclusions We successfully implemented a system for CMVS at scale in 2 hospital wards, but our results show that intervention fidelity decreased over time, more in the internal medicine ward than in the surgical ward. This decrease appeared to depend on multiple ward-specific factors. Nurses’ perceptions regarding the value and benefits of the intervention varied. Implications for optimal implementation of CMVS include engaging nurses early, seamless integration into electronic health records, and sophisticated decision support tools for vital sign trend interpretation.

Publisher

JMIR Publications Inc.

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3