Versatile GCH Control Software for Correction of Loads Applied to Forearm Crutches During Gait Recovery Through Technological Feedback: Development and Implementation Study

Author:

Chamorro-Moriana GemaORCID,Sevillano Jose LuisORCID,Perez-Cabezas VORCID

Abstract

Background Measuring weight bearing is an essential aspect of clinical care for lower limb injuries such as sprains or meniscopathy surgeries. This care often involves the use of forearm crutches for partial loads progressing to full loads. Therefore, feasible methods of load monitoring for daily clinical use are needed. Objective The main objective of this study was to design an innovative multifunctional desktop load-measuring software that complements GCH System 2.0–instrumented forearm crutches and monitors the applied loads, displaying real-time graphical and numerical information, and enabling the correction of inaccuracies through feedback technology during assisted gait. The secondary objective was to perform a preliminary implementation trial. Methods The software was designed for indoor use (clinics/laboratories). This software translates the crutch sensor signal in millivolts into force units, records and analyzes data (10-80 Hz), and provides real-time effective curves of the loads exerted on crutches. It covers numerous types of extrinsic feedback, including visual, acoustic (verbal/beeps), concurrent, terminal, and descriptive feedback, and includes a clinical and research use database. An observational descriptive pilot study was performed with 10 healthy subjects experienced in bilateral assisted gait. The Wilcoxon matched-pairs signed-rank test was used to evaluate the load accuracy evolution of each subject (ie, changes in the loads exerted on crutches for each support) among various walks, which was interpreted at the 95% confidence level. Results GCH Control Software was developed as a multifunctional desktop tool complementing GCH System 2.0–instrumented forearm crutches. The pilot implementation of the feedback mechanism observed 96/100 load errors at baseline (walk 0, no feedback) with 7/10 subjects exhibiting crutch overloading. Errors ranged from 61.09% to 203.98%, demonstrating heterogeneity. The double-bar feedback found 54/100 errors in walk 1, 28/100 in walk 2, and 14/100 in walk 3. The first walk with double-bar feedback (walk 1) began with errors similar to the baseline walk, generally followed by attempts at correction. The Wilcoxon matched-pairs signed-rank test used to evaluate each subject’s progress showed that all participants steadily improved the accuracy of the loads applied to the crutches. In particular, Subject 9 required extra feedback with two single-bar walks to focus on the total load. The participants also corrected the load balance between crutches and fluency errors. Three subjects made one error of load balance and one subject made six fluctuation errors during the three double-bar walks. The latter subject performed additional feedback with two balance-bar walks to focus on the load balance. Conclusions GCH Control Software proved to be useful for monitoring the loads exerted on forearm crutches, providing a variety of feedback for correcting load accuracy, load balance between crutches, and fluency. The findings of the complementary implementation were satisfactory, although clinical trials with larger samples are needed to assess the efficacy of the different feedback mechanisms and to select the best alternatives in each case.

Publisher

JMIR Publications Inc.

Subject

Health Informatics

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3