Diagnostic Accuracy of Detecting Diabetic Retinopathy by Using Digital Fundus Photographs in the Peripheral Health Facilities of Bangladesh: Validation Study

Author:

Begum TahminaORCID,Rahman AminurORCID,Nomani DilrubaORCID,Mamun AbdullahORCID,Adams AlayneORCID,Islam ShafiqulORCID,Khair ZaraORCID,Khair ZareenORCID,Anwar IqbalORCID

Abstract

Background Diabetic retinopathy can cause blindness even in the absence of symptoms. Although routine eye screening remains the mainstay of diabetic retinopathy treatment and it can prevent 95% of blindness, this screening is not available in many low- and middle-income countries even though these countries contribute to 75% of the global diabetic retinopathy burden. Objective The aim of this study was to assess the diagnostic accuracy of diabetic retinopathy screening done by non-ophthalmologists using 2 different digital fundus cameras and to assess the risk factors for the occurrence of diabetic retinopathy. Methods This validation study was conducted in 6 peripheral health facilities in Bangladesh from July 2017 to June 2018. A double-blinded diagnostic approach was used to test the accuracy of the diabetic retinopathy screening done by non-ophthalmologists against the gold standard diagnosis by ophthalmology-trained eye consultants. Retinal images were taken by using either a desk-based camera or a hand-held camera following pupil dilatation. Test accuracy was assessed using measures of sensitivity, specificity, and positive and negative predictive values. Overall agreement with the gold standard test was reported using the Cohen kappa statistic (κ) and area under the receiver operating curve (AUROC). Risk factors for diabetic retinopathy occurrence were assessed using binary logistic regression. Results In 1455 patients with diabetes, the overall sensitivity to detect any form of diabetic retinopathy by non-ophthalmologists was 86.6% (483/558, 95% CI 83.5%-89.3%) and the specificity was 78.6% (705/897, 95% CI 75.8%-81.2%). The accuracy of the correct classification was excellent with a desk-based camera (AUROC 0.901, 95% CI 0.88-0.92) and fair with a hand-held camera (AUROC 0.710, 95% CI 0.67-0.74). Out of the 3 non-ophthalmologist categories, registered nurses and paramedics had strong agreement with kappa values of 0.70 and 0.85 in the diabetic retinopathy assessment, respectively, whereas the nonclinical trained staff had weak agreement (κ=0.35). The odds of having retinopathy increased with the duration of diabetes measured in 5-year intervals (P<.001); the odds of having retinopathy in patients with diabetes for 5-10 years (odds ratio [OR] 1.81, 95% CI 1.37-2.41) and more than 10 years (OR 3.88, 95% CI 2.91-5.15) were greater than that in patients with diabetes for less than 5 years. Obesity was found to have a negative association (P=.04) with diabetic retinopathy. Conclusions Digital fundus photography is an effective screening tool with acceptable diagnostic accuracy. Our findings suggest that diabetic retinopathy screening can be accurately performed by health care personnel other than eye consultants. People with more than 5 years of diabetes should receive priority in any community-level retinopathy screening program. In a country like Bangladesh where no diabetic retinopathy screening services exist, the use of hand-held cameras can be considered as a cost-effective option for potential system-wide implementation.

Publisher

JMIR Publications Inc.

Subject

Public Health, Environmental and Occupational Health,Health Informatics

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3