Abstract

Background Heart rate (HR) is an important and commonly measured physiological parameter in wearables. HR is often measured at the wrist with the photoplethysmography (PPG) technique, which determines HR based on blood volume changes, and is therefore influenced by blood pressure. In individuals with spinal cord injury (SCI), blood pressure control is often altered and could therefore influence HR accuracy measured by the PPG technique. Objective The objective of this study is to investigate the HR accuracy measured with the PPG technique with a Fitbit Charge 2 (Fitbit Inc) in wheelchair users with SCI, how the activity intensity affects the HR accuracy, and whether this HR accuracy is affected by lesion level. Methods The HR of participants with (38/48, 79%) and without (10/48, 21%) SCI was measured during 11 wheelchair activities and a 30-minute strength exercise block. In addition, a 5-minute seated rest period was measured in people with SCI. HR was measured with a Fitbit Charge 2, which was compared with the HR measured by a Polar H7 HR monitor used as a reference device. Participants were grouped into 4 groups—the no SCI group and based on lesion level into the <T5 (midthoracic and lower) group, T5-T1 (high-thoracic) group, and >T1 (cervical) group. Mean absolute percentage error (MAPE) and concordance correlation coefficient were determined for each group for each activity type, that is, rest, wheelchair activities, and strength exercise. Results With an overall MAPEall lesions of 12.99%, the accuracy fell below the standard acceptable MAPE of –10% to +10% with a moderate agreement (concordance correlation coefficient=0.577). The HR accuracy of Fitbit Charge 2 seems to be reduced in those with cervical lesion level in all activities (MAPEno SCI=8.09%; MAPE<T5=11.16%; MAPET1−T5=10.5%; and MAPE>T1=20.43%). The accuracy of the Fitbit Charge 2 decreased with increasing intensity in all lesions (MAPErest=6.5%, MAPEactivity=12.97%, and MAPEstrength=14.2%). Conclusions HR measured with the PPG technique showed lower accuracy in people with SCI than in those without SCI. The accuracy was just above the acceptable level in people with paraplegia, whereas in people with tetraplegia, a worse accuracy was found. The accuracy seemed to worsen with increasing intensities. Therefore, high-intensity HR data, especially in people with cervical lesions, should be used with caution.

Publisher

JMIR Publications Inc.

Subject

Rehabilitation,Physical Therapy, Sports Therapy and Rehabilitation

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3