Assessment of Heart Rate Monitoring During Exercise With Smart Wristbands and a Heart Rhythm Patch: Validation and Comparison Study

Author:

Wang Tse-LunORCID,Wu Hao-YiORCID,Wang Wei-YunORCID,Chen Chao-WenORCID,Chien Wu-ChienORCID,Chu Chi-MingORCID,Wu Yi-SyuanORCID

Abstract

Background The integration of wearable devices into fitness routines, particularly in military settings, necessitates a rigorous assessment of their accuracy. This study evaluates the precision of heart rate measurements by locally manufactured wristbands, increasingly used in military academies, to inform future device selection for military training activities. Objective This research aims to assess the reliability of heart rate monitoring in chest straps versus wearable wristbands. Methods Data on heart rate and acceleration were collected using the Q-Band Q-69 smart wristband (Mobile Action Technology Inc) and compared against the Zephyr Bioharness standard measuring device. The Lin concordance correlation coefficient, Pearson product moment correlation coefficient, and intraclass correlation coefficient were used for reliability analysis. Results Participants from a Northern Taiwanese medical school were enrolled (January 1-June 31, 2021). The Q-Band Q-69 demonstrated that the mean absolute percentage error (MAPE) of women was observed to be 13.35 (SD 13.47). Comparatively, men exhibited a lower MAPE of 8.54 (SD 10.49). The walking state MAPE was 7.79 for women and 10.65 for men. The wristband’s accuracy generally remained below 10% MAPE in other activities. Pearson product moment correlation coefficient analysis indicated gender-based performance differences, with overall coefficients of 0.625 for women and 0.808 for men, varying across walking, running, and cooldown phases. Conclusions This study highlights significant gender and activity-dependent variations in the accuracy of the MobileAction Q-Band Q-69 smart wristband. Reduced accuracy was notably observed during running. Occasional extreme errors point to the necessity of caution in relying on such devices for exercise monitoring. The findings emphasize the limitations and potential inaccuracies of wearable technology, especially in high-intensity physical activities.

Publisher

JMIR Publications Inc.

Subject

Health Informatics,Medicine (miscellaneous)

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3