Evaluating a Novel Infant Heart Rate Detector for Neonatal Resuscitation Efforts: Protocol for a Proof-of-Concept Study

Author:

Abdou AbdelrahmanORCID,Krishnan SridharORCID,Mistry NirajORCID

Abstract

Background Over 10 million newborns worldwide undergo resuscitation at birth each year. Pediatricians may use electrocardiogram (ECG), pulse oximetry (PO), and stethoscope in determining heart rate (HR), as HR guides the need for and steps of resuscitation. HR must be obtained quickly and accurately. Unfortunately, the current diagnostic modalities are either too slow, obtaining HR in more than a minute, or inaccurate. With time constraints, a reliable robust heart rate detector (HRD) modality is required. This paper discusses a protocol for conducting a methods-based comparison study to determine the HR accuracy of a novel real-time HRD based on 3D-printed dry-electrode single-lead ECG signals for cost-effective and quick HR determination. The HRD’s HR results are compared to either clinical-grade ECG or PO monitors to ensure robustness and accuracy. Objective The purpose of this study is to design and examine the feasibility of a proof-of-concept HRD that quickly obtains HR using biocompatible 3D-printed dry electrodes for single-lead neonatal ECG acquisition. This study uses a novel HRD and compares it to the gold-standard 3-lead clinical ECG or PO in a hospital setting. Methods A cross-sectional study is planned to be conducted in the neonatal intensive care unit or postpartum unit of a large community teaching hospital in Toronto, Canada, from June 2023 to June 2024. In total, 50 newborns will be recruited for this study. The HRD and an ECG or PO monitor will be video recorded using a digital camera concurrently for 3 minutes for each newborn. Hardware-based signal processing and patent-pending embedded algorithm-based HR estimation techniques are applied directly to the raw collected single-lead ECG and displayed on the HRD in real time during video recordings. These data will be annotated and compared to the ECG or PO readings at the same points in time. Accuracy, F1-score, and other statistical metrics will be produced to determine the HRD’s feasibility in providing reliable HR. Results The study is ongoing. The projected end date for data collection is around July 2024. Conclusions The study will compare the novel patent-pending 3D-printed dry electrode–based HRD’s real-time HR estimation techniques with the state-of-the-art clinical-grade ECG or PO monitors for HR accuracy and examines how fast the HRD provides reliable HR. The study will further provide recommendations and important improvements that can be made to implement the HRD for clinical applications, especially in neonatal resuscitation efforts. This work can be seen as a stepping stone in the development of robust dry-electrode single-lead ECG devices for HR estimations in the pediatric population. International Registered Report Identifier (IRRID) DERR1-10.2196/45512

Publisher

JMIR Publications Inc.

Subject

General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3